510(k)K212587

FDA DEVICE FACTS

3D-RD-S

Radiopharmaceutical Imaging and Dosimetry, LLC

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEFebruary 22, 2023PRODUCT CODEIYX

Indications for use

3D-RD-S is intended to estimate radiation absorbed dose (and related quantities) to tissues after administration of a radioactive product. For use with internally administrated radioactive products, 3D-RD-S should not be used to deviate from product dosing and administration instructions. Refer to the product’s prescribing information for instructions. The intended use of OLINDA/EXM is to provide estimates (deterministic) of absorbed radiation dose at the whole organ level as a result of administering any radionuclide and to calculate effective whole-body dose. This is dependent on input data regarding biodistribution being supplied to the application. Indications for Use is Equivalent Product Code Regulation IYX / 21 CFR 892.1100 IYX / 21 CFR 892.1100 Product Code / Regulation is Equivalent Target Population Adults, Children Adults, Children, Pregnant women Target Population is Equivalent Input TIA, TIAC, or TAC Fraction of injected activity in each organ or the TIAC Input Data is Equivalent Radionucleotides Supported Supports 1,252 radionucleotides Over 1000, including Alpha Emitters Radionucleotides Supported is Equivalent Dosimetry Calculation Whole organ / tissue Dosimetry. Tissue S- Values Whole organ / tissue Dosimetry. Tissue S- Values Dosimetry Calculation is Equivalent Output Absorbed Dose tables Absorbed Dose tables Output Data is Equivalent TAC Integration Integration can be done based on user-selection of one of 4 fit functions, user specified washout half-life, physical decay, or a combination of the above and trapezoidal integration. The four fit functions constrain the shape of the fit and are selected by the user based on the data. The user can provide, or the software estimate initial values, of the fitting parameters. Uncertainty values provided with the data are used in the Integration is performed based on fitting data with up to 3 exponentials. Fitting start and endpoints can be user specified. Allows specifying weights for data during fitting. The data and fit are plotted graphically. TAC Integration is Equivalent Radiopharmaceutical Imaging and Dosimetry, LLC Attributes 3D-RD-S OLINDA/EXM, v2.0 Comments fitting. Uncertainty values are used as weights in fitting. Integration is always from 0 to infinity. The fits and integration is displayed graphically. Anatomical Sites Supports the 79 target and 43 target tissues from ICRP-133 Supports 26 source tissues and 30 target tissues Anatomical Sites is Equivalent

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 19, 2026