FDA DEVICE FACTS
Air compression leg massager HY-1117A
Xiamen High Top Electronic Technology Co., Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Air compression leg massager HY-1117A is intended for home to temporarily relieve minor muscle aches and/or pains, and to temporarily increase circulation to the treated areas in people who are in good health. The Air Compression Therapy Device is indicated for the temporary relief of minor muscle aches and pains and for temporary increase in circulation to the treated areas in people who are in good health. The Air Compression Therapy Device simulates kneading and stroking of tissues by using an inflatable garment. Same Rx or OTC OTC OTC Same Pressure range 0-240mmHg 0~240mmHg Same Treatment time 15 minutes 20 minutes Similar The treatment time of subject device is smaller than predicate device (K193354), so the difference of treatment time would not raise adversely impact on safety and effectiveness. Standard ANSI AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, IEC 60601-1-2, IEC 60601-1-11, ISO 10993-5, ISO 10993-10 ES 60601-1; IEC60601-1-2; ISO 10993-5: ISO 10993-10; IEC 60601-1-11 Similar Mode of compression Sequential Sequential/ Peristaltic Same Power source 100~240V 50/60Hz 100~240V 50/60Hz Same Power consumption 24W 12W Similar Dimensions (W*H*D) 11*16*24.9inch 10.2×5.9×25.6inch Similar Photo Similar Similar Housing materials Molded ABS enclosure Molded ABS enclosure Same Number of chambers 3 3 Same Work mode Six modes: Full leg 1(F1) Full leg 2(F2) Full leg 3(F3) Separate part 1(M1) Separate part 2(M2) Separate part 3(M3) Mode 1: Starting with the foot chamber and progressing up the thigh chamber, each section compresses and the pressure gradually rises to the pre-determined air pressure level, then decompresses and the air pressure drops. Once the thigh section decompresses, the cycle begins again. Mode 1 follows this pressure sequence: Although the subject device provides 6 kinds of work mode, the Mode F1, F2, F3, M1, M2, M3 are the similar with predicate device (K193354), while the subject device just have difference about inflatable order of the different chambers. The treatment pressure range are the same under different work modes, so the difference of pressure range would not raise adversely impact on safety and effectiveness. Mode 2: Starting with the foot chamber and progressing up the thigh, each section compresses and the pressure gradually rises to the pre-determined air pressure level, holds the air until the entire garment is compressed. All three sections then decompress simultaneously and the air pressure drops, then cycle begins again. Mode 2 follows this pressure sequence: Mode 3: include two stage, stage 1: it work according to the method of mode 1, after the stage 1 is completed, it go to stage 2(working according to the method of mode 2) without interruption time until finish the stage 2, then enter next cycle without interruption . Mode1 Mode2 The pressure sequence of mode 3 combines mode 1 and mode 2 Safety feature Button on display allows user to stop or pause therapy session at any time Button on display allows user to stop or pause therapy session at any time Same Technology Compressor and valve system which sequentially inflates inflatable chambers Compressor and valve system which sequentially inflates inflatable chambers Same Summary of the technological characteristics of the device The device meets all the applicable technical requirements of : IEC 60601-1-11: 2015 - Medical electrical equipment - Part 1-11: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment IEC 60601-1-2: 2014 - Medical electrical equipment - Part 1-2: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Electromagnetic Compatibility ANSI AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 - Medical electrical equipment - Part 1: General requirements for basic safety and essential performance ISO 10993-5: 2009 - Biological Evaluation of Medical Device - Part 5: Tests for in vitro Cytotoxicity ISO 10993-10: 2010 - Biological Evaluation of Medical Devices - Part 10: Tests for irritation and skin sensitization
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。