FDA DEVICE FACTS
GEMINI SL Total Knee System, Endo-Model Knee System, and Sled Knee System with LINK PorEx (TiNbN) inhouse coating
Waldemar Link GmbH & Co. KG
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The GEMINI SL Total Knee System is indicated for patients suffering from disability due to:
• Degenerative, post-traumatic or rheumatoid arthritis;
• Avascular necrosis of the femoral condyle;
• Post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy;
• Moderate valgus, varus or flexion deformities. This device may also be indicated in the salvage of previously failed surgical attempts. The device is indicated for cemented use. Only cementless labeled modular stems are indicated for uncemented use. The Endo-Model and Sled Knee Systems with LINK PorEx (TiNbN) coating are indicated for patients with sever e joint diseases with limitation of mob ility due to degenerative, rheumatoid or post -traumatic arth rosis or arthritis. Joint fractures which disallow an oste osynthetic reconstruction. These devices are intended for cemented use only. The Endo-Model Rotating Hinge and Modular Rotating Hinge Knee System with LINK PorEx (TiNbN) coating are indicated for the following conditions:
1) Bone necroses 2) Bicondylar arthros is by partly damaged collateral ligaments 3) Revision after primary total knee replacement 4) Revision surgery after hinge knee or rotational knee joint 5) Revision surgery by insufficient / inadequate bone mass 6) Arthrosis of patella flange 7) Valgus/Varus deformities <10° 8) Valgus/Varus deformities 10-15° 9) Valgus/Varus deformities 15-20° The Sled Knee System with LINK PorEx (TiNbN) coating is indicated for the following conditions: 1) Unicondylar arthrosis by intact ligaments including both cruciate ligaments 2) Valgus/Varus deformities <10°
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。