FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEFebruary 25, 2022PRODUCT CODEPHX

Indications for use

The PRIMA humeral system is intended for partial or total, primary or revision, shoulde r joint replacement in skeletally mature patients. The patient's joint must be anatomically and structurally suited to receive the selected implants and a functional del toid muscle is necessary to use the device. The PRIMA Stem is intended for use in cemen tless and cemented applications, at the discretion of the surgeon. The PRIMA Anatomic implant is indicat ed for partial or tot al, primary o r revision shoulder joint replacement, in patients suffering from pain and disability due to:

• Non-inflammatory degenerative joint disease (i.e. osteoarthritis),

• Inflammatory arthritis of the glenohumeral join including rheumatoid arthritis,

• Avascular necrosis of the humeral head,

• Traumatic/post-traumatic arthritis,

• Fractures of the humeral head where adequate fixa tion can be achieved and adequate bone stock remains,

• Post-fracture deformity with intact rotator cuff , where adequate fixation can be achieved and adequate bone stock remains,

• Cuff tear arthropathy (CTA Heads only). The PRIMA Reverse implant is indicated for primary reverse total shoulder replac ement or for revision when converting an anatomic PRIMA arthroplasty to a reverse total shoulder arthroplasty ( i.e., in c ase of cuff tear arthropathy or in a grossly rotator cuff deficiency joint with severe arthropathy). Revision surgery with retention o f the PRIMA Stem is intended as conversion surgery from anatomic t o reverse, where the PRIMA Stem is stable, well positioned and tissue integrated. Other revisions of the humeral prosthesis part should be trea ted with traditional shoulder prostheses. The PRIMA reverse implant is indicated for patients suffering from pai n and disability due to:

• Rotator cuff tear arthropathy,

• Osteoarthritis with rotator cuff tear,

• Rheumatoid arthritis with rotator cuff tear,

• Massive irreparable rotator cuff tear,

• Avascular necrosis of the humeral head,

• Correction of functional deformity , where adequate fixatio n can be achieved and adequate bone stock remains,

• Fractures of the humeral head where adequate fixation can be achieved a nd adequate bone stock remains. The PRIMA Humeral System consists of the following single use components:

• Anatomic configuration:

- stem

- adaptor for humeral heads.

• Reverse configuration:

- stem

- reverse tray and

- reverse insert. The PRIMA Humeral System is intended to be used with all SMR glenoid implants. SMR Glenosphere Ø42 The SMR Shoulder System is int ended for partial or total, primary or revision shoulder joint replacement. The SMR Anatomic Shoulder System is indicated for partial or total, primary or revisio n shoulder joint replacement in patients suffering from disability due to:

• non-inflammatory degenerative joint disease including osteoarthritis and avasc ular necrosis;

• inflammatory degenerative joint disease such as rheumatoid arthritis;

• treatment of ac ute fractures of the humeral head that cann ot be treated with o ther fracture fixation methods;

• revision of a failed primary implant; in case of SMR Short Stems only if sufficient bone stock remains);

• cuff tear arthropathy (CTA Heads only);

• glenoid arthros is without excessive glenoid bone loss: A1, A2 and B1 according to Walch classification (SMR TT Hybrid Glenoid only). The SMR Reverse Shoulder System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff defic ient joint with severe arthropathy (disabled shoulder). The patient’s joint must be anatomica lly and structurally suit ed to receive the selected implants and a functional deltoid muscle is neces sary to use the device. The SMR TT Hybrid Glenoid Reverse Ba seplate must not be used in cases of excessive glenoid bone loss and/or when bone graft is needed. The Modular SMR Sh oulder System allows the assembly of components in various hu -meral and glenoid constructs. The constructs are intended for cemented and u ncemented use as specified in the following table. In the Anatomic shoulder the humeral construct consists of the humeral stem, the humeral body, the ad aptor taper and the humeral head. In the Reverse shoulder the humeral construct consists of the humera l stem, the reverse humeral body and the re verse liner. On the humeral side the fixation of t he humeral stem determine s if the construct is cemented or uncemented. The Anatomic glenoid construct consists of an all polyethylene glenoid, a polyethylene glenoid with metal peg or a metal back assemble d with a liner; the Revers e glen oid consists of a metal back/connector/glen osphere construc t or of a peg/baseplate/glenosphere construct. On the glenoid side, the fixation of the all polyethylene glenoid, the pol yethylene glenoid with metal peg or the metal back determines if the construct is cemented or uncemented. System Components Material System use A R Cem Not Cem

• • SMR Stems (Cemented, Cemented Revision) Ti6Al4V X

• • SMR Stems (Cementless Finned, Cementless Revision) Ti6Al4V X

• • SMR Short Stems (Cementless Finned) Ti6Al4V X

• SMR Humeral Bodies (Trauma, Finned) Ti6Al4V X X

• • SMR Reverse Humeral Body Ti6Al4V X X

• • Humeral Extension Ti6Al4V X X

• SMR Humeral Heads (Standard*, CTA) CoCrMo X X

• SMR Adaptor Tapers (Neutral, Eccentric) Ti6Al4V X X

• SMR CTA Head Adaptor for Reverse Humeral Body Ti6Al4V X X

• SMR Glenospheres* CoCrMo X

• SMR Connectors* Ti6Al4V X System Components Material System use A R Cem Not Cem

• Reverse Liners UHMWPE X X

• SMR Cemented Glenoids UHMWPE X

• SMR 3 Pegs Cemented Glenoids UHMWPE X

• • * SMR TT Hybrid Glenoid UHMWPE+Ti6Al4V+Ta X X

• SMR TT Hybrid Glenoid Reverse Baseplate + Screw Ti6Al4V X

• • SMR Metal Back Glenoids Ti6Al4V+PoroTi X* X*

• • SMR TT Baseplate Ti6Al4V X* X*

• SMR TT Augmented 360 Baseplate Ti6Al4V X

• • SMR TT Glenoid Peg Ti6Al4V X X

• SMR Metal Back Liner UHMWPE X* X*

• * • SMR Bone screws Ti6Al4V X Material Standards Ti6Al4V (ISO 5832-3 - ASTM F1472) - CoCrMo (ISO 5832-12 - ASTM F1537) – UHMWPE (ISO 5834-2 - ASTM F648) - PoroTi Titanium Coating (ASTM F1580) - Ta (ISO13782 - ASTM F560) A= Anatomic / R=Reverse *NOTE:

• When considering the humeral side, SMR Glenosphere Ø42 can be coup led only wit h PRIMA Humeral System.

• In the US, the SMR Metal Backed Glenoid/Liner construct, used as part of the SMR Anatomic Shoulder Replacement, is inten ded for use with bone cement and should be used wi thout bone screws.

• The SMR Metal Backed Glenoid/Connec tor/Glenosphere cons truct, used a s p art of the SMR Reverse Shoulder replacement, is intended for uncemented u se with the addi tion of screws for fixation.

• SMR Lateralized Connectors are not indicated for use with glenoid bone grafting techniques.

• In the US the SMR TT Metal Bac k Basep late used as part of the SMR Anatomic Shoulder Replacement, is intended for use w ith bone cement and should be used without bone screws; while when used as p art of the SMR Re verse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.

• If a SMR TT Hybrid Glenoid is in place and revision to a rever se prosthesis is required, the patient can be revised by removing the polyethylene baseplate, leaving the metal peg in place and by connecting it t o the SMR TT Hybrid Glenoid Reverse Baseplate. The SMR TT Hybrid Glenoid Reverse B aseplate is intended for un cemented use wit h t he additi on of screws fo r fixation.

• The Dia. 50, 52 and 54mm Humeral Heads with + 3mm increased height cannot be coupled to the L ong Adaptor T apers ( both concentric and eccentric). The Dia. 52 and 54 mm Humeral Heads with + 2mm incr eased height can not be coupled to the Long Adaptor Tapers (both concentric and eccentric).

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 23, 2026