FDA DEVICE FACTS
CARESCAPE ONE and CARESCAPE DOCK F0, Model Numbers MBZ323 and MFA101, CARESCAPE ECG, Model Number MKE101,CARESCAPE TEMP, Model Number MKT101, CARESCAPE PRES, Model Number MKP101, CARESCAPE SPO2, Model Numbers MKS101 and MKS201
Ge Medical Systems Information Technologies, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
CARESCAPE ONE is both a multi-parameter physiological patient monitor and an accessory to a multi-parameter patient monitor intended for use in multiple areas and intra-hospital transport within a professional healthcare facility. CARESCAPE ONE is indicated for the monitoring of hemodynamic and respiratory physiological parameters. When the CARESCAPE ONE is operated as a standalone multi-parameter physiological patient monitor, it provides the following physiological parameters:
• ECG (heart rate, ST segment, and arrhythmia detection)
• Pulse oximetry (pulse rate, functional oxygen saturation [SpO2])
• Non-invasive blood pressure (systolic, diastolic, and mean arterial pressures)
• Invasive pressure (pulse rate and systolic, diastolic, and mean pressures)
• Temperature
• Respiratory carbon dioxide (EtCO2, FiCO2, and respiration rate)
• Impedance respiration
When the CARESCAPE ONE is connected as an accessory to a compatible host monitor, it provides the following physiological parameters to the host monitor:
• ECG (heart rate, ST segment, and arrhythmia detection)
• Pulse oximetry (pulse rate, functional oxygen saturation [SpO2], and total hemoglobin concentration [SpHb])
• Non-invasive blood pressure (systolic, diastolic, and mean arterial pressures)
• Invasive pressure (pulse rate and systolic, diastolic, and mean pressures)
• Regional oxygen saturation (rSO2)
• Temperature
• Respiratory carbon dioxide (EtCO2, FiCO2, and respiration rate)
• Impedance respiration
When the CARESCAPE ONE is connected as an accessory to a compatible host monitor, visual and audible alarms, user controls, and user interface are provided on the compatible host monitor and not on CARESCAPE ONE. CARESCAPE ONE is intended for use on adult, pediatric, and neonatal patients and on one patient at a time. Regional oxygen saturation (rSO2) is an adjunct parameter for noninvasive monitoring of cerebral/somatic regional oximetry of blood in the brain or other tissue beneath the sensor. It is intended to be used on patients greater than 40 kg (88 lbs) at risk for reduced-flow or no-flow ischemic states. CARESCAPE ONE is intended for use under the direct supervision of a licensed healthcare practitioner, or by personnel trained in the proper use of the equipment in a professional healthcare facility.
Contraindications for using CARESCAPE ONE: The CARESCAPE ONE is not intended for use within a controlled MR environment.