RARA CRAFT DATABASE for FDA Medical Devices
510(k)K214106

FDA DEVICE FACTS

QuikPass Catheter

Traverse Vascular, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJanuary 28, 2022PRODUCT CODEDQY

Indications for use

The QuikPass Catheter is intended to be used to access discrete regions of the coronary and/or peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and is also intended to assist in the delivery of contrast media into the coronary and/or peripheral vasculature. The Turnpike catheter is intended to be used to access discrete regions of the coronary and/or peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and to subselectively infuse/deliver diagnostic and therapeutic agents. Similar; the subject device indications for use are narrower than those of the predicate. There are therefore no new questions of safety or effectiveness. Catheter Components Proximal hub with Luer connection Proximal hub with Luer connection Identical Single-lumen shaft constructed of two polymer layers encapsulating a braid and coil and having a hydrophilic coating Single-lumen shaft constructed of two polymer layers encapsulating a braid and coil and having a hydrophilic coating Identical Radiopaque distal markers and ports for guidewire passage and solution infusion Radiopaque distal tip with outlet for guidewire passage and solution infusion Similar; minor design differences do not raise new questions of safety or effectiveness Available Models, Sizes, and Working Length Model #135-03: 3 Fr; 135cm Model #135-04: 4 Fr; 135cm Model #150-03: 3 Fr; 150cm Model #150-04: 4 Fr; 150cm Model #5642: 3 Fr; 135cm Model #5643: 3 Fr; 150cm Similar; minor design differences do not raise new questions of safety or effectiveness Labeled Shaft Outer Diameter Model #135-03: 2.95 Fr (0.98mm) Model #135-04: 3.95 Fr (1.32mm) Model #150-03: 2.95 Fr (0.98mm) Model #150-04: 3.95 Fr (1.32mm) Model #5642: 2.9 Fr (0.97mm) Model #5643: 2.9 Fr (0.97mm) Similar; minor design differences do not raise new questions of safety or effectiveness Labeled Shaft Inner Diameter Model #135-03: 2.10 Fr (0.70mm) Model #135-04: 3.10 Fr (1.04mm) Model #150-03: 2.10 Fr (0.70mm) Model #150-04: 3.10 Fr (1.04mm) Model #5642: 1.26 Fr (0.42mm) Model #5643: 1.26 Fr (0.42mm) Similar; minor design differences do not raise new questions of safety or effectiveness Distal Tip Shape Smooth, Rounded, Tapered Smooth, Rounded, Tapered Identical Traverse Vascular, Inc. QuikPass™ Catheter 510(k) Description Subject Device Predicate Device (K142065) Conclusion Distal Tip Length 4-6mm 8-10mm Similar; minor design differences do not raise new questions of safety or effectiveness Distal Tip Inner/Outer Diameter OD: 1.8 Fr (0.6mm) ID: 1.2 Fr (0.4mm) OD: 1.6 Fr (0.53mm) ID: 1.25 Fr (0.42mm) Similar; minor design differences do not raise new questions of safety or effectiveness Hydrophilic Coating Material, Location, Length, and Function Hydrogel polymer, distal shaft, 40cm in length, lubricious coating Hydrogel polymer, distal shaft, 60cm in length, lubricious coating Similar; minor design differences do not raise new questions of safety or effectiveness Intended Patient Population Intended for use in adults (greater than 21 years of age) Intended for use in adults (greater than 21 years of age) Identical Compatible Guidewire Diameter 0.014” ≤ 0.014” Similar; compatible guidewire diameter for the subject device falls within the labeled range for the

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 23, 2026