RARA CRAFT DATABASE for FDA Medical Devices
510(k)K220020

FDA DEVICE FACTS

Cryo 7

Zimmer Medizinsysteme GmbH

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEFebruary 4, 2022PRODUCT CODEGEX

Indications for use

The Cryo 7 is intended to minimize pain and thermal injury during laser and dermatological treatments and for temporary topical anesthetic relief for injections. The Cryo V6.0 Cold Air Device is intended to minimize pain and thermal injury during laser and dermatological treatments and for temporary topical anesthetic relief for injections. Identical Performance Characteristics Measurement at device outlet -30°C ± 3°C At an air speed of 210 ± 40 to 600 ± 100 liters/minute. -30°C At an air speed of 100 to 1000 liters/minute. Similar, not significantly different Cooling Method, Operation principle Cooling agent-based condenser and evaporation system. Cold air is produced which is then directed onto the skin. Conduction, evaporation, and forced convection cool the skin. Cooling agent-based condenser and evaporation system. Cold air is produced which is then directed onto the skin. Conduction, evaporation, and forced convection cool the skin. Identical Cooling Material Gas (Air) Gas (Air) Identical Mains Voltage 100V - 120V / 50-60Hz 100V – 120V / 50-60Hz Identical Main Fuse 16A circuit breaker in main switch 16A circuit breaker in main switch Identical Power Consumption Max. 10A Max. 9 - 11A No impact IP classification IP20 IPX0 Identical Design Internal metal chassis covered by industrial designed plastic housing Metal enclosure Similar, not important for the device safety and effectiveness evaluation Materials Environmentally approved R452a, closed loop cooling system Environmentally approved R507, closed loop cooling system Both environment-ally approved, no impact Cooling spot Size Varies with distance from distal end of air hose to tissue – 10cm² @ 5cm distance Varies with distance from distal end of air hose to tissue – 10cm² @ 5cm distance Identical Fan speed settings 1 - 9 1 - 9 Identical Comparison with the

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 23, 2026