FDA DEVICE FACTS
DolorClast Radial
E.M.S Electro Medical Systems S.A
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Statement The DolorClast® Radial is indicated for:
• Relief of minor muscle aches and pains
• Temporary increase in local blood circulation
• Activation of connective tissue The D-Actor® 200 Vibration Massage System is intended for:
• Relief of minor muscle aches and pains
• Temporary increase in local blood circulation
• Activation of connective tissue Same Mode of Action Radial pressure waves, or extracorporeal pulse activation respectively Radial pressure waves, or extracorporeal pulse activation respectively Same Mechanism of action Pneumatically generated vibrations Pneumatically generated vibrations Same System components Control console with integrated air compressors to control treatment parameters Mains cable Handpiece containing projectile within guiding tube Interchangeable applicators Coupling gel Cart (optional) Control unit Mains cable Handpiece containing projectile within guiding tube Interchangeable applicators Coupling gel Footswitch (optional) Tablet PC (optional) Same except for optional accessories Method of triggering vibration pulses Handpiece Handpiece or optional footswitch Same except for predicate optionally can be controlled using a footswitch Type of acoustic wave generation Pneumatic/ballistic Pneumatic/ballistic Same Pressure setting range 1-4 bar 1-5 bar Similar Frequency setting range 1-25 Hz 1-21 Hz Similar Number of treatment applicators 7 4 Similar Treatment applicator sizes OD in mm: 5, 10, 15, 25, 40 OD in mm: 6, 15, 20, 35 Similar Projectile mass (g) 3.2 3 Similar Displacement of applicator heads 0.18 - 0.28 mm 0.6 – 2.0 mm Similar Operating mode Continuous vibration at a fixed frequency Continuous vibration at a fixed frequency Same DolorClast® Radial Traditional 510(k)
Parameter Proposed Device (K220538)
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。