RARA CRAFT DATABASE for FDA Medical Devices
510(k)K221162

FDA DEVICE FACTS

UniVy OsteoVy Cervical IBF System

Vy Spine, LLC

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATENovember 4, 2022PRODUCT CODEODP

Indications for use

The UniVy™ OsteoVy™ Cervical IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The system devices are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The impla nts are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level. The UniVy™ OsteoVy™ Cervical IBF System is intended for use at one level in the cervical spine, from C3 to T1, for treatment of cervical degenerative disc disease (DDD is defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies). The UniVy™ OsteoVy™ Cervical IBF System is to be used in patients who have six weeks of non-operative treatment. Non-Clinical Testing: The predicate Reliance Cervical IBF System (K202266) has undergone non-clinical testing using various ASTM standards at a third party facil ity. The subject UniVy™ OsteoVy™ Cervical IBF System has the same material, general design, sizes, indication of use and biocompatibility as the primary predicate device , and the predicate device performance test results will be leveraged in favor of the UniVy™ OsteoVy™ Cervical IBF System. Technological Modifications: The UniVy ™ OsteoVy™ Cervical IBF System intends to market the primary predicate device design, with the only design change being a reduction to the diameter of the implant inserter holes. The subject UniVy OsteoVy Cervical IBF system is s ubstantially equivalent to the predicate devices in terms of sterilization and biocompatibility.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 22, 2026