FDA DEVICE FACTS
Sterile Disposable Syringe with Safety Needle, Sterile Disposable Syringe with Needle, Sterile Disposable Safety Needle, Sterile Disposable Needle
Jiangsu Kangbao Medical Equipment Co., Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Sterile Disposable Needle is intended to be used with a luer slip or luer lock syringe for aspiration and injection of fluids for medical purpose. The Sterile Disposable Needle is intended to be used with a luer slip or luer lock syringe for aspiration and injection of fluids for medical purpose. Same Configuration Needle hub Needle hub Same Needle tube Needle tube Needle cap Needle cap Operation Mode For manual use only For manual use only Same Sterilized Yes Yes Same Single Use Single Use Single Use Same Label/Labeling Complied with 21 CFR part 801 Complied with 21 CFR part 801 Same Needle Size 18G, 27G 20G, 21G, 22G, 25G, 16G, 18G, 19G, 20G, 22G, 23G, 24G, 25G, 27G, 28G, 29G, 30G 21G, 26G, Different Length 1/2", 5/8", 3/4", 1", 1-1/4", 1-1/2" 5/16", 1/2", 5/8", 3/4", 1", 1-1/4", 1-1/2" Needle Performance Complied with ISO 7864, ISO 9626 Complied with ISO 7864, ISO 9626 Same Patient-contact Materials Needle hub Polypropylene (PP) Polypropylene (PP) Same Needle tube Stainless Steel SUS 304 Stainless Steel SUS 304 Lubricants Silicone oil Silicone oil Adhesive UV adhesive UV glue Biocompatibility Cytotoxicity No cytotoxicity No cytotoxicity Same Irritation No intracutaneous reactivity No intracutaneous reactivity Sensitization No sensitization No skin sensitization Systemic Toxicity No systemic toxicity No systemic toxicity Hemolysis No Hemolysis No Hemolysis Pyrogen No Pyrogen No Pyrogen Complement Activation Not show potentials to activate complete system Not show potentials to activate complete system In vivo Thrombogenicity No thrombogenicity No thrombogenicity Sterilization Method EO Sterilized EO Sterilized Same SAL 10-6 10-6 Same Endotoxin Limit 20 EU per device 20 EU per device Same Different -Needle Size and Length The needle size and length for proposed device is different from the predicate devices. This difference will not raise new questions on safety and effectiveness of the proposed device.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。