RARA CRAFT DATABASE for FDA Medical Devices
510(k)K221966

FDA DEVICE FACTS

Dynamic TiBase

Talladium Espana, SL

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATESeptember 15, 2022PRODUCT CODENHA

Indications for use

Dynamic TiBase abutments are intended for use with dental implants as a support for single-unit or multi-unit prostheses in the maxillary or mandibular arch of a partially or fully edentulous patient.

Implant Compatibility Implan t Body Diameter, mm Imp lant Platform, mm Kontact™ Dental Implant System 3.6 3.6 4.2 4.2 4.8 4.8 5.4 5.4

All digitally designed custom abutments for use with Dynamic TiBase abutments are to be sent to a Talladium validated milling center for manufacture.

SUBJECT DEVICE DESCRIPTION The purpose of this submission is to obtain marketing clearance for Dynamic TiBase, two-piece titanium base abutments that require the fabrication of patient-specific custom zirconia superstructures using CAD-CAM technology. In final, finished form, the subject device abutments are intended to be used as a two-piece abutment composed of the base bottom-half (titanium base) with a bonded CAD-CAM zirconia top-half. Each patient-specific zirconia superstructure is individually prescribed by the clinician and manufactured by an authorized milling center.

The subject device abutments are compatible with Kontact™ Dental Implant System implants manufactured by Biotech Dental, SAS, cleared in K210220 in the following sizes: 3.6 mm body diameter/3.6 mm platform; 4.2 mm body diameter/4.2 mm platform; 4.8 mm body diameter/4.8 mm platform; and 5.4 mm body diameter/5.4 mm platform.

The compatibility between the subject device and the Kontact™ Dental Implant System implants was established by a business agreement between Talladium España, SL and Biotech Dental, SAS.

All subject device abutments and abutment screws are made of titanium alloy (Ti-6Al-4V) conforming to ASTM F136 and ISO 5832-3.

All Dynamic TiBase abutments are provided in a straight design (no angulation in the TiBase portion) with an engaging implant connection (for crowns), with a gingival height ranging from 1 mm to 3 mm; additional gingival height may be provided in the zirconia superstructure as described below. All Dynamic TiBase abutments are provided with a cut-out in the prosthetic post to accommodate a restoration with an angled screw channel when clinically necessary. The prosthetic post heights are 4.5 mm (maximum height) / 2.5 mm (cutout height) or 4.0 mm/2.5 mm. Dynamic TiBase abutments with a 4.5 mm post height may be shortened to no less than 4 mm for a single-unit restoration.

All zirconia copings (superstructures) for use with the subject device Dynamic TiBase will be made at a Talladium validated milling center under FDA quality system regulations, and the material will conform to ISO 13356. The design parameters for the CAD-CAM zirconia superstructure for the Dynamic TiBases are: Minimum wall thickness – 0.55 mm Minimum post height for single-unit restorations – 4.0 mm Maximum gingival height – 5.37 mm (in the zirconia superstructure) Minimum gingival height – 1.0 mm (in the TiBase) Maximum angulation – 30°

The recommended cement for bonding the zirconia superstructure to the Dynamic TiBases to create the final two-piece abutment is G-CEM LinkAce™, cleared as GAM-200 in K120243.

See the full product information製品情報をすべて見るには