FDA DEVICE FACTS
Premier Resolution System
Trinity Biotech (Primus Corporation, Dba Trinity Biotech)
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The VariantTM II B-thalassemia Program is intended for the separation and area percent determinations of hemoglobins A2 and F and as an aid in the identification of abnormal hemoglobins in whole blood using ion-exchange high performance liquid chromatography (HPLC).
The VariantTM II B-thalassemia Program is intended for use only with the Bio-Rad VariantTM II Hemoglobin Testing System.
For in vitro diagnostic use only. The Premier Resolution System is an automated High Performance Liquid Chromatography (HPLC) system which performs the separation of hemoglobin species in venous whole blood samples for the quantitative analysis of normal hemoglobin (A, A2, and F), and the qualitative detection of major variant hemoglobin S, C, D-Los Angeles, and E in adult, adolescent, children and infant populations. The assays are performed on venous whole blood samples collected in tubes containing K2EDTA as anticoagulant. The Premier Resolution System is intended for Professional Laboratory Use only. The Premier Resolution System is intended for use with analytical components and reagents provided by Trinity Biotech. The Premier Resolution System is intended to be used in conjunction with other laboratory and clinical findings. For In Vitro Diagnostic Use. Chemistry Ion Exchange HPLC Ion Exchange HPLC Collection Tubes K2EDTA, K3EDTA K2EDTA Sample Tube Processing Aspiration of hemolysate from closed tube Aspiration of whole blood from closed tube Sample Hemolysis Performed automatically by the system Performed automatically by the system Automated Sample Introduction Continuous loading with sample racks Continuous loading with sample racks Separation System Ion-exchange high performance liquid chromatography (HPLC) Ion-exchange high performance liquid chromatography (HPLC) protein separation Premier Resolution System Premarket Notification Aspect or Feature Predicate Bio-Rad VariantTM II Beta Thalassemia K991127 Premier Resolution System protein separation on analytical column based on ionic interaction with the column material and elution by buffer gradient with increasing ionic strength. on analytical column based on ionic interaction with the column material and elution by buffer gradient with increasing ionic strength. Separation Unit Analytical Column Analytical Column Analysis Throughput About 6 Minutes About 4 Minutes - Quick Scan About 8 Minutes - High Resolution Calibration A2 + F Calibrator A2+F Calibrator Control A2+F Control A2+F Control Use of Other Controls FASC Position Marker FASC Position Marker Sample Identification Barcode on sample tube Barcode on sample tube Absorbance wavelength About 413 nm 413 nm Hb Variants Library Display and Operator Manual Display and Operator Manual
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。