RARA CRAFT DATABASE for FDA Medical Devices
510(k)K223673

FDA DEVICE FACTS

Surgeon Controlled Arm

Levita Magnetics International Corp

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEAugust 4, 2023PRODUCT CODEPNL

Indications for use

The Surgeon Controlled Arm is indicated for use to hold and position a rigid laparoscope/endoscope and the Magnetic Controller of the Levita Magnetic Surgical System in K223673 Page 2/5 minimally invasive interventions where the Levita Magnetic Surgical System is indicated for use. Comparison of Intended Use and Technological Characteristics with the Predicate Device: The subject and predicate devices have the same intended use. Both devices are surgeon-controlled computer-driven systems whose function is to hold and position a rigid laparoscope/ endoscope. The subject device is only indicated for use with the Levita Magnetics Surgical System (most recently cleared under K191762). The technological characteristics of the subject device and predicate device are substantially equivalent. Both devices have the same principles of operation using similar components: they provide software-based control of surgeon-controlled arm device(s) with motorized axes to hold and move a rigid commercially-available endoscope during minimally-invasive procedures. The user drives the electrically-powered device using a remote controller. The starting point of the movement for each case is saved as the trocar point from which the software calculates the required individual movements of the device arm’s motorized axes to achieve the desired total movement. The user may also move the arm by hand guiding, without use of the remote controller. Neither predicate nor subject device interacts directly with any intra-cavity organ, but instead, holds instruments externally. The following are differences in technological characteristics:

• Both devices include a surgeon-controlled arm for controlling a rigid commercially-available endoscope. The subject device additionally includes a second, similar arm for controlling the Levita Magnetics Magnetic Controller component of the Levita Magnetics Surgical System

• The predicate device remote controller is controlled by hand and the subject device remote controller is controlled by foot.

• The subject device additionally includes a switch to allow the surgeon to determine the active arm for remote control.

• The arm motion control specifications for the subject device, i.e. maximum velocities and acceleration, latency, range of motion, and safety limits, may differ from those of the predicate device, which are unknown.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 18, 2026