FDA DEVICE FACTS
MRI compatibility for existing BioHorizons dental implants and abutments
BioHorizons Implant Systems, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
BioHorizons implants are intended for use in the mandible or maxilla for use as an artificial root structure for single tooth replacement or for fixed bridgework and dental retention. The implants may be restored immediately (1) with a temporary prosthesis that is not in functional occlusion or (2) when splinted together for multiple tooth replacement or when stabilized with an overdenture supported by multiple implants. BioHorizons Tapered Short Implants are intended for use in the mandible or maxilla as an artificial root structure for single tooth replacement or for fixed bridgework and dental retention. The implants may be restored using delayed loading, or with a terminal or intermediate abutment for fixed or removable bridgework, and for overdentures. BioHorizons Tapered Internal 3.0, Tapered Tissue Level 3.0, and Laser-Lok 3.0 Implants may be used as an artificial root structure for single tooth replacement of mandibular central and lateral incisors and maxillary lateral incisors. The implants may be restored immediately (1) with a temporary prosthesis that is not in functional occlusion, (2) when splinted together as an artificial root structure for multiple tooth replacement of mandibular incisors, or (3) for denture stabilization using multiple implants in the anterior mandible and maxilla. The implants may be placed in immediate function when good primary stability has been achieved and with appropriate occlusal loading. Intra-Lock implants are intended for use in the mandible or maxilla for use as an artificial root structure for single tooth replacement or for fixed bridgework and dental retention. The implants may be restored immediately (1) with a temporary prosthesis that is not in functional occlusion or (2) when splinted together for multiple tooth replacement or when stabilized with an overdenture supported by multiple implants. Intra-Lock 3.3mm diameter implants may be used as an artificial root structure for single tooth replacement of mandibular central and lateral incisors and maxillary lateral incisors. The implants may be restored immediately (1) with a temporary prosthesis that is not in functional occlusion, (2) when splinted together as an artificial root structure for multiple tooth replacement of mandibular incisors, or (3) for denture stabilization using multiple implants in the anterior mandible and maxilla. The implants may be placed in immediate function when good primary stability has been achieved and with appropriate occlusal loading. Mini Drive-Lock™ Dental Implants are intended for use as a self-tapping titanium screw for transitional or intra-bony long-term applications. Mini Drive-Lock™ Dental Implants are indicated for long-term maxillary and mandibular tissue-supported denture stabilization. Multiple implants should be used and may be restored after a period of time or placed in immediate function. MILO™ Dental Implants are indicated for long-term maxillary and mandibular tissue-supported denture stabilization. Multiple implants may be restored after a period of time or placed in immediate function. They are also indicated for the rehabilitation of single maxillary lateral incisors and mandibular lateral and central incisors. The implants may be restored after a period of time or placed in immediate function. BioHorizons Prosthetics are abutments that include healing abutments for contouring tissue and final restorative abutments to support a prosthesis. The abutments may be used for a single or multiple unit restoration and are compatible for use with BioHorizons Internal and Tapered Internal implant systems and Zimmer® Dental Screw-Vent® and Tapered Screw-Vent® implants with 3.5mm, 4.5mm and 5.7mm internal hex-connection mating platform diameters. BioHorizons Titanium Base Abutments and Laser-Lok Titanium Base Abutments are intended to be used as straight abutments. The BioHorizons Multi-unit Abutments for CONELOG® are intended to function in the mandible or maxilla to support single and multiple-unit temporary or definitive restorations on CONELOG dental implants. BioHorizons CAD/CAM Abutments are dental abutments placed onto a dental implant to provide support for dental prosthetic restorations. The abutments include: 1) Titanium abutment blanks with a pre-machined implant connection where the upper portion may be custom-milled in accordance with a patient-specific design using CAD/CAM techniques; and 2) Titanium bases with a pre-machined implant connection upon which a CAD/CAM designed superstructure may be fitted to complete a two-piece dental abutment. The abutments include an abutment screw for fixation to the underlying implant. The abutments may be used for single-unit (single-tooth) or multiple-unit (bridges and bars) restorations and are compatible for use with BioHorizons Internal and Tapered Internal implant systems and Zimmer® Dental Screw-Vent® and Tapered Screw-Vent® implants with 3.5mm, 4.5mm and 5.7mm internal hex-connection mating platform diameters. All digitally designed abutments and/or copings for use with BioHorizons CAD/CAM Abutments are intended to be sent to a BioHorizons-validated milling center for manufacture. BioHorizons abutments designed using CAD/CAM techniques must fulfill the BioHorizons allowable range of design parameters. Intra-Lock Prosthetics are abutments that include healing abutments for contouring tissue and final restorative abutments to support a prosthesis. The abutments may be used for a single or multiple unit restoration and are compatible for use with Intra-Lock implants. Intra-Lock Titanium Base Abutments and Laser-Lok Titanium Base Abutments are intended to be used as straight abutments. Intra-Lock CAD/CAM Abutments are dental abutments placed onto a dental implant to provide support for dental prosthetic restorations. The abutments include: 1) Titanium abutment blanks with a pre-machined implant connection where the upper portion may be custom-milled in accordance with a patient-specific design using CAD/CAM techniques; and 2) Titanium bases with a pre-machined implant connection upon which a CAD/CAM designed superstructure may be fitted to complete a two-piece dental abutment. The abutments include an abutment screw for fixation to the underlying implant. The abutments may be used for single-unit (single-tooth) or multiple-unit (bridges and bars) restorations and are compatible for use with Intra-lock implants. All digitally designed abutments and/or copings for use with Intra-Lock CAD/CAM Abutments are intended to be sent to a BioHorizons-validated milling center for manufacture. Intra-Lock abutments designed using CAD/CAM techniques must fulfill the BioHorizons allowable range of design parameters. The MILO and Mini Drive Lock Implant System Prosthetics have been designed to restore partially or fully edentulous patients. The abutments have been designed to be used in either the mandible or maxilla and to support removable or fixed prosthesis.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。