Rapid Aneurysm Triage and Notification

Ischemaview, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

AI/ML
DECISION DATEJuly 27, 2023PRODUCT CODEQFMCLINICAL AREARadiology

Indications for use

Rapid Aneurysm Triage and Notification (ANRTN) is a radiological computer-assisted triage and notification software device for analysis of CT images of the head. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and prioritizing studies with suspected saccular aneurysms during routine patient care. Rapid ANRTN uses an artificial intelligence algorithm to analyze images and highlight studies with suspected saccular aneurysms in a standalone application for study list prioritization or triage in parallel to ongoing standard of care. The device generates compressed preview images that are meant for informational purposes only and not intended for diagnostic use. The device does not alter the original medical image and is not intended to be used as a diagnostic device. Analyzed images are available for review through the PACS, email and mobile application. When viewed the images are for informational purposes only and not for diagnostic use. The results of Rapid ANRTN, in conjunction with other clinical information and professional judgment, are to be used to assist with triage/prioritization of saccular aneurysm cases. Radiologists who read the original medical images are responsible for the diagnostic decision. Rapid ANRTN is limited to analysis of imaging data and should not be used in-lieu of full patient evaluation or relied upon to make or confirm diagnosis. Rapid ANRTN is limited to detecting saccular aneurysms at least 4 mm in diameter in adults. Inclusion Criteria: The module shall detect unruptured saccular brain aneurysms greater than or equal to 4 mm in size within the following anatomical region: * Internal Carotid Artery (ICA): ophthalmic segment to ICA terminus * Middle Cerebral Artery (MCA): M1 segment through M1/M2 bifurcation * Anterior Cerebral Artery (ACA): A1 and A2 segments * Anterior Communicating Artery (ACOM) * Posterior Communicating Artery (PCOM) * Posterior Cerebral Artery (PCA): P1 segment * Vertebral Artery (VA): intracranial portion of the VA through the vertebrobasilar (VB) junction * Basilar Artery (BA) Contraindications/Exclusions/Cautions: * The module shall process only CTA datasets with a patient position of headfirst supine. * The module shall process only a series within CTA datasets comprised only of axial slices. * The module shall process only CTA datasets with Z FOV (cranio-caudal transverse anatomical coverage) greater than or equal to 90 mm. * The module shall process only CTA datasets with in-plane pixel spacing (X & Y resolution): 0.2-1.0 mm. * The module shall process only CTA datasets with in-plane X FOV: 160-400 mm. * The module shall process only CTA datasets with in-plane Y FOV: 160-400 mm. * The module shall process only CTA datasets with Z slice spacing of 0.2-1.25 mm. * The module shall process only CTA datasets with data acquired at x-ray tube voltage 80 kVp-140 kVp, as reported in the input data DICOM header. * The module shall process only CTA datasets consisting of input slices of continuous order without gaps. * The module shall process only CTA datasets where the images belong to a single series (i.e., identical SeriesInstanceUID DICOM tag value for all images). * The module shall not process CTA datasets where the DICOM tags ImagePositionPatient (IPP), ImageOrientationPatient (IOP), or PixelSpacing are missing. * The module shall only process a single series per study, being the largest available that passes the above requirements. * The module shall accept input files within a parent folder named by a unique identifier for the case. * The module shall accept axial-oblique CTA datasets with an oblique plane of less than or equal to 35 degrees. * Cases with significant motion and/or imaging artifacts.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 22, 2026