FDA DEVICE FACTS

Auryon Atherectomy System

Eximo Medical, Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJune 9, 2023PRODUCT CODEMCW

Indications for use

The Auryon™ Atherectomy System and Auryon Atherectomy Catheters with aspiration are indicated for use as atherectomy devices for arterial The Auryon™ Atherectomy System and Auryon Atherectomy Catheters with aspiration are indicated for use as atherectomy devices for arterial Eximo Medical Ltd. Auryon Atherectomy System, Special 510(k) stenoses, including in-stent restenosis (ISR), and to aspirate thrombus adjacent to stenoses in native and stented infra-inguinal arteries. The Auryon™ Atherectomy System and Auryon Atherectomy Catheters without aspiration are indicated for use in the treatment, including atherectomy, of infra-inguinal stenoses and occlusions. stenoses, including in-stent restenosis (ISR), and to aspirate thrombus adjacent to stenoses in native and stented infra-inguinal arteries. The Auryon™ Atherectomy System and Auryon Atherectomy Catheters without aspiration are indicated for use in the treatment, including atherectomy, of infra-inguinal stenoses and occlusions. Regulation Number 21 CFR §870.4875 21 CFR §870.4875 Regulatory Class Class II Class II Product Code MCW MCW Active Medium Nd:YAG Nd:YAG Laser Wavelength 355 nm 355 nm Laser Fluence levels 50 and 60 mJ/mm2 50 and 60 mJ/mm2 Pulse Rate 40 Hz 40 Hz Pulse Duration 10-25 ns 10-25 ns Maximum output 33.5 mJ 33.5 mJ Catheter sizes 0.9mm, 1.5 mm, 2.0mm, 2.35mm (only size 0.9 impacted by change) 0.9mm, 1.5 mm, 2.0mm, 2.35mm Platinum/Iridium marker band Included in 0.9 mm catheter only None Catheter Sterilization Method Ethylene Oxide Ethylene Oxide Comparison of Performance Data The modified 0.9 mm Auryon Atherectomy Catheter was tested using the same methods and acceptance criteria as was done in the predicate device 510(k). The specific tests are listed below Summary of Performance Testing Catheter shaft ID, OD, and working length Catheter guard tube length Catheter trackability in simulated anatomical shape Freedom from leakage during liquid infusion Pull testing of all joints Freedom from exposed optical fibers Optical Functionality test Catheter torque test Eximo Medical Ltd. Auryon Atherectomy System, Special 510(k) Summary of Performance Testing Evaluation of the hydrophilic coating of the catheters

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 18, 2026