FDA DEVICE FACTS
SMR Hybrid Glenoid System
Lima Corporate S.P.A.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The SMR Shoulder System is intended for partial or total, primary or revision shoulder joint replacement. The SMR Anatomic Shoulder System is indicated for partial or total, primary or revision shoulder joint replacement in patients suffering from disability due to:
• non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis;
• inflammatory degenerative joint disease such as rheumatoid arthritis;
• treatment of acute fractures of the humeral head that cannot be treated with other fracture fixation methods;
• revision of a failed primary implant; in case of SMR Short Stems only if sufficient bone stock remains;
• cuff tear arthropathy (CTA Heads only);
• glenoid arthrosis without excessive glenoid bone loss: A1, A2 and B1 according to Walch classification (SMR TT Hybrid Glenoid only). The SMR Reverse Shoulder System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff deficient joint with severe arthropathy (disabled shoulder). The patient’s joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to use the device. The SMR TT Hybrid Glenoid Reverse Baseplate must not be us ed in cases of ex cessive glenoid bone loss and/or when bone graft is needed. The Modular SMR Shoulder System allows the assembly of compon ents in various humeral and glenoid constructs. The constructs are intended for cemented and uncemented use as specif ied in the follo wing table. In the Anatomic shoulder the humeral construct consists of the humeral stem, the humeral body, the adaptor taper and the humeral head. In the Reverse shoulder the humeral construct consists of the humeral stem, the reverse hume ral body and th e re verse liner. On the humeral side the fixation of the humeral stem determines if the construct is cemented or uncemented. The Anatomic glenoid construct consists of an all polyethylene glenoid, a polyethylene glenoid with metal peg or a m etal back ass embled with a liner; the Reverse glenoid consists of a metal back/connector/glenosphere construct or of a peg/baseplate/glenosphere construct. On the glenoid side, the fixation of all polyethylene glenoid, the polyethylene glenoid with metal peg or the metal back determines if the construct is cemented or uncemented. System Components Material Use A R Cem Not Cem
• • SMR Stem (Cemented, Cemented Revision) Ti6Al4V X
• • SMR Stem (Cementless Finned, Cementless Revision) Ti6Al4V X
• • SMR Short Stem (Cementless Finned) Ti6Al4V X
• SMR Humeral Body (Trauma, Finned) Ti6Al4V X X
• • SMR Reverse Humeral Body Ti6Al4V X X
• • Humeral Extension Ti6Al4V X X
• SMR Humeral Head (Standard*, CTA) CoCrMo X X
• SMR Adaptor Taper (Neutral, Eccentric) Ti6Al4V X X
• SMR CTA Head Adaptor for Reverse Humeral Body Ti6Al4V X X
• SMR Glenosphere* CoCrMo X
• SMR Connector* Ti6Al4V X
• Reverse Liner UHMWPE X X LimaVitTM (Vitamin E highly crosslinked UHMWPE) X X
• SMR Cemented Glenoid UHMWPE X
• SMR 3 Pegs Cemented Glenoid UHMWPE X
• • * SMR TT Hybrid Glenoid UHMWPE+ Ti6Al4V 3D printed +Ta X X System Components Material Use A R Cem Not Cem
• SMR TT Hybrid Glenoid Reverse Baseplate + Screw Ti6Al4V X
• • SMR Metal Back Glenoid Ti6Al4V+PoroTi X* X*
• • SMR TT Baseplate Ti6Al4V X* X*
• SMR TT Augmented 360 Baseplate Ti6Al4V X
• • SMR TT Glenoid Peg Ti6Al4V 3D printed X X
• S MR Metal Back Liner UHMWPE X* X*
• * • SMR Bone screw Ti6Al4V X Material Standards Ti6Al4V (ISO 5832-3 - ASTM F1472) – Ti6Al4V 3D printed (to meet the mechanical and chemical requirements of ISO 5832-3) - CoCrMo (ISO 5832-12 - ASTM F1537) – UHMWPE (ISO 5834-2 - ASTM F648) - LimaVitTM (Vitamin E highly crosslinked UHMWPE) (ISO 5834-2 - ASTM F648 - ASTM F2695 – ASTM F2565) - PoroTi Titanium Coating (ASTM F1580) - Ta (ISO13782 - ASTM F560) A= Anatomic / R=Reverse *N OTE:
• When considering the humeral side, SMR Glenosphere Ø42 can be coupled only with PRIMA Humeral System.
• In the US, the SMR Metal Backed Glenoid/Liner construct, used as part of the SMR Anatomic Shoulder Replacement, is intended for use with bone cement and should be used without bone screws.
• The SMR Metal Backed Glenoid/Connector /Glenosphere construct, used as part of the SM R Re verse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.
• SMR Lateralized Connectors are not indicated for use with glenoid bone grafting techniques.
• In the US the SMR TT Metal Back Baseplate used as part of the SMR Anatomic Shoulder Replacement, is intended for use with bone cement and should be used without bone screws; whi le when used as part of the SMR Reverse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.
• If a SMR TT Hybrid Glenoid is in place and revision to a reverse prosthesis is required, the patient can be revised by removing the polyethylene baseplate, leaving the metal peg in place a nd b y connecting it to th e SMR TT Hybrid Glenoid Reve rse Baseplate. The SMR TT Hybri d G lenoid Reverse Baseplate is intended for uncemented use with the addition of screws for fixation.
• The Dia. 50, 52 and 54mm Humeral Heads with + 3mm increased height cannot be coupled to the Long Adaptor Tapers (both concentric and eccentric). The Dia. 52 and 54mm Humeral Heads with + 2mm increased height cannot be coupled to the Long Adapto r Tapers (b oth concentric and eccentric).
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。