FDA DEVICE FACTS
Vis-U-All Low Temperature Sterilization Pouches
STERIS Corporation
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Vis-U-All Low Temperature Sterilization Pouches/Tubing are sterilization containment pouches for use by health care providers to enclose:
• medical devices in a single or double pouch configuration*
• trays containing medical devices in a single or double pouch configuration
• small items requiring surface sterilization in a single pouch configuration within a tray *3-D printed items should not be double pouched. to be sterilized in the:
• Lumen, Non Lumen, Flexible, Fast Non Lumen, Fast and Specialty Cycles of the V-PRO® Low Temperature Sterilization Systems
• Default Cycle of the STERRAD** 100S Sterilizer
• Standard and Advanced Cycles of the STERRAD NX and NX with ALLClear** Technology Sterilizers
• Express, Standard, Flex Scope and DUO Cycles of the STERRAD 100NX and 100NX with ALLClear Technology Sterilizers **STERRAD and ALLClear are trademarks of Advanced Sterilization Products NOTE: Trays must be legally marketed for use in the V PRO Low Temperature or STERRAD Sterilization Systems and contain a vent surface area to tray volume ratio ≥ 0.135 in-1 with the maximum number of instrument organizers installed. The pouches maintain the sterility of the enclosed devices until used. When used to enclose medical devices, the pouches are intended to contain the devices in such a manner as to leave a minimum of one inch between the devices and seal on all sides. When used to enclose a tray, the tray must fit loosely within the pouch. V-PRO 60 & s2 Lumen Cycle
• Non-lumened instruments and instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors.
• Non-lumened devices including non-lumened rigid and semi-rigid endoscopes
• Medical devices, including single, dual and triple channeled rigid and semi-rigid endoscopes, with the following configurations: ○ single or dual lumen devices ≥ 0.77 mm internal diameter (ID) and ≤ 410 mm in length ≥ 1.8 mm ID x ≤ 542 mm in length ○ triple lumen devices ≥1.2 mm ID and ≤ 275 mm in length ≥1.8 mm ID and ≤ 310 mm in length or ≥2.8 mm ID and ≤ 317 mm in length
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。