RARA CRAFT DATABASE for FDA Medical Devices
510(k)K231635

FDA DEVICE FACTS

A-Line Advanced

Biocetec Co., Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJune 6, 2023PRODUCT CODENJM

Indications for use

A-Line Advanced orthodontic ceramic bracket is intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position. S-Line orthodontic ceramic bracket is intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position. Same as predicate Material composition of Bracket Polycrystalline Alumina ※ Primer Polymer : 3- (Trimethoxysilyl)propyl-2- Methyl-2-Propenoic Acid & Acetone Polycrystalline Alumina No significant difference : The subject device passed the test criteria for the biological evaluation according to the recognized consensus Submitter: BIOCETEC CO., LTD. A-Line Advanced Premarket Notification: Traditional 510(k) standard ISO 10993-1 Material composition of Door Ni-Co-Cr-Mo Alloy Polycrystalline Alumina No significant difference : The subject device passed the test criteria for the biological evaluation according to the recognized consensus standard ISO 10993-1. Material composition of colorants for bracket placement orientation Polyvinylpyrrolidone(25wt%) Sweet whey powder(25wt%) TiO2(25wt%) Food dye(25wt%) Polyvinylpyrrolidone(25wt%) Sweet whey powder(25wt%) TiO2(25wt%) Food dye(25wt%) Same as predicate Transparency Half-transparency Half-transparency Same as predicate Bracket design MBT , ROTH designs with and without hook, conforming to ISO 27020:2010 Dentistry – Brackets and tube for Use in Orthodontics MBT , ROTH designs with and without hook, conforming to ISO 27020:2010 Dentistry – Brackets and tube for Use in Orthodontics Same as predicate Self-ligating mechanism Yes Yes Same as predicate Design parts Hook, Slot, Round home, base and marking Hook, Slot, Round home, base and marking Same as predicate Bracket In-out(mm) 0.7 to 1.24 0.65 to 1.08 No significant difference : The subject device passed the test criteria for the bench test according to the recognized consensus standard ISO 27020. Bracket Torque(°) -30 to 17 -22 to +17 No significant difference : The subject device passed the test criteria for the bench test according to the recognized consensus standard ISO 27020. Bracket Angulation(°) 0 to 13 0 to 11 No significant difference : The subject device passed the test criteria for the bench test according to the recognized consensus standard ISO 27020. Available slot sizes 0.018 / 0.022 inch 0.018 / 0.022 inch Same as predicate Orientation marking Yes Yes Same as predicate Single use Yes Yes Same as predicate Submitter: BIOCETEC CO., LTD. A-Line Advanced Premarket Notification: Traditional 510(k) Non-Sterile Packaging Yes Yes Same as predicate Target Population Patients in need of teeth alignment correction Patients in need of teeth alignment correction Same as predicate Anatomical Site Teeth Teeth Same as predicate Location of Use Use only by professional orthodontists Use only by professional orthodontists Same as predicate Bio-compatibility All user directly contacting materials are compliance with ISO10993 requirements. All user directly contacting materials are compliance with ISO10993 requirements. Same as predicate (*) Comparison of the property of two orthodontic brackets by bench test Orthodontic Ceramic bracket(A -Line Advanced) and the predicate device(S -Line (K182193)) have identical indication for use statements and the same intended use. The 510(K) Documentation also includes data from bench testing to evaluate the performance of Orthodontic Ceramic bracket(A -Line Advanced) to the predicate device. The properties evaluated include wire slot torque test, shear bond strength test, and bracket removal test, wire slot drag test and door pull-out test. Although the subject device and predicate device are no significant differences in some parameters[Material composition of Bracket, Material composition of Door, Bracket In -out(mm), Bracket Torque(◦), Bracket Angulation(◦)], the differences do not affect the substantial equivalence of the subject device when compared to the predicate device. These differences do not raise different questions of safety or effectiveness.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 18, 2026