Intraosseous Fusion Device System

Auxano Medical, LLC

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATESeptember 29, 2023PRODUCT CODEHWC

Indications for use

The Intraosseous Fusion Device System is indicated for use in skeletally mature individuals for fracture repair and arthrodesis, osteotomy, joint fusion and fragment fixation appropriate with the size of the implant including: Minimally invasive reconstruction of fractures and joints; Fractures of the foot and ankle; Osteochrondritis dissecans, Ostero-Chondral Fractures, Other small fragment, cancellous bone fractures, Small joint fusion. Metatarsal and phalangeal osteotomies; Fractures of the tarsals, metatarsals and other fractures of the foot; Avulsion fractures and fractures of metatarsal V; Tarso-metatarsal and metatarso-phalangeal arthrodesis; Tarsal Minimally invasive reconstruction of fractures and joints; Adjuvant for osteosynthesis in complex joint fractures; Multifragment joint fractures; Simple metaphyseal fractures, Fractures of the wrist, ankle, elbow, and shoulder, Condylar fractures; Osteochrondritis dissecans, Osteochondral Fractures, Ligament avulsion injuries, Ligament fixation, Other small fragment, cancellous bone fractures, Small joint fusion. Areas where accurate screw placement is vital. Metatarsal and phalangeal osteotomies; Fractures of the tarsals, metatarsals and other fractures of the foot; Avulsion fractures and fractures of metatarsal V; Tarso-metatarsal and metatarsophalangeal arthrodesis; Tarsal Fusions; Calcaneal and talar fractures, Subtalar arthrodesis, Ankle arthrodesis. Fractures of small joints, such as: Ankle fractures, Navicular fractures, Fractures of the fibula, malleolus, and calcaneus, Distal tibia and pilon fractures, Acetabular fractures. Other fractures of the pelvic ring; Fractures of the femoral head and The OrthoSolutions ‘System26’ cannulated screws (headed and headless compression) and washers are indicated for use over a guide pin or wire for aligned bone fracture repair and arthrodesis, osteotomy, joint fusion and bone fragment fixation appropriate with the size of the screw. Washers of matching size to the headed cannulated bone screw may be used in certain applications for deficient osteopenic bone. The non-cannulated 2.0 (headed, headless compression and Twist-Off) bone screws are applicable, as well, for bone fracture repair and arthrodesis, osteotomy, joint fusion and bone fragment fixation appropriate with the size of the screw. ‘System26’ non-cannulated 2.0mm (headed, headless compression and Twist-Off) bone screws and cannulated (headed and headless compression) bone screw sizes of 2.0mm, 2.5mm 3.0mm are indicated for treating small bone fractures as well as performing osteotomies, arthrodesis and joining cancellous bone fragments in the upper and lower limb and extremities. Subject Device: Auxano Medical- Intraosseous Fusion Device System Predicate (K191995): Subchondral Solutions- S4 Screw Additional Predicate (K163489): OrthoSolutions- System26 Bone Screws Fusions; Calcaneal and talar fractures, Subtalar arthrodesis. Ankle arthrodesis. Fractures of small joints, such as: Ankle fractures, Navicular fractures, Fractures of the fibula, malleolus, and calcaneus. The Intraosseous Fusion Device System is not intended for spinal use. neck, Supracondylar femoral fractures, Slipped capital femoral epiphyses, An adjunct to DHIS in basilar neck fractures, Intercondylar femur fractures, Intracapsular fractures of the hip, Fractures of the distal femur and proximal tibia, Patellar fractures, Tibial plateau fractures. Small fragments of the hand and wrist, Fractures of the carpals and metacarpals, Carnal and metacarpal arthrodesis, Scaphoid fracture and other fractures of the hand, Phalangeal and interphalangeal fractures, Fractures of the ulna and radius. Radial head fractures, Fractures of the olecranon and distal humerus, Humeral head fractures, Ligament fixation at the proximal humerus, Glenoid fractures. ‘System26’ cannulated bone screw sizes (headless compression and headed with optional matching washer) of 4.0mm, 5.0mm, 6.5mm, and 8.0mm are indicated to be used with large and long bones. Specific indications, which are dependent in part on the diameter of the screw include: Minimally invasive bone fracture/joint reconstructions; Additive osteosynthesis for complex joint fractures; Multiple-fragment joint fractures; Femoral neck and femoral head fractures; Femoral supracondylar fractures; Tibial plateau fractures; Fractures of the head of the humerus; Fractures of the tibia; Cooper fractures of the tibia; Bone fractures of the radius, wrist, ankle, elbow, and shoulder; Ligament fixation of the proximal humerus; Bone fractures of the acetabulum and dorsal pelvic ring; Condylar fractures; Ligament avulsion injuries; Malleolar and navicular fractures; Bone fractures of the calcaneus and talus; Arthrodesis of the ankle joint; Arthrodesis of foot joints and; Avulsion fractures. The OrthoSolutions ‘System26’ Bone Screws are not intended for spinal use. Substantial Equivalence: Similar Similar Intended Use: Bone fixation of fractures, fusions (arthrodesis), osteotomies and fragments. Bone fixation of fractures, fusions (arthrodesis) and osteotomies. Bone fixation of fractures, fusions (arthrodesis), osteotomies and fragments. Substantial Equivalence: Similar Same Components: K-wires, sizers, drills, taps, drivers, driver handles K-wires, countersink, depth gauge, reamer, driver K-wires, drill guides, drills, countersinks, depth gauges, drivers, driver handles, forceps, clamps, easy-outs Substantial Equivalence: Similar Similar Subject Device: Auxano Medical- Intraosseous Fusion Device System Predicate (K191995): Subchondral Solutions- S4 Screw Additional Predicate (K163489): OrthoSolutions- System26 Bone Screws Technical Characteristics: Threaded Cannulated Headless Fenestrated Interrupted thread Threaded Cannulated Headless Fenestrated Interrupted thread HA-coated Threaded Cannulated and Non-cannulated Headed and Headless (Smooth/Threaded) Substantial Equivalence: Similar Similar Materials: Ti-6Al-4V (ASTM F136 & F3001) Ti-6Al-4V (ASTM F136) (w/HA coating) Ti-6Al-4V (ASTM F136) Substantial Equivalence: Similar Same

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 18, 2026