510(k)K232813

FDA DEVICE FACTS

Therapy EC, Therapy XT

Dmc Importacao E Exportacao DE Equipamentos Ltda

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 19, 2024PRODUCT CODENHN

Indications for use

Therapy EC and Therapy XT are non-heating infrared lamps and are indicated for adjunctive use in the temporary relief of hand and wrist pain associated with Carpal Tunnel Syndrome. The TH0R DDII 830CL3 Laser System is a non-heating infrared lamp and is indicated for adjunctive use in the temporary relief of hand and wrist pain associated with Carpal Tunnel Syndrome. Operation principle Light emission Light emission Emitters technology Diode Laser (Semiconductor) Diode Laser (Semiconductor) Optical power 100 mW per emitter Three 30 mW Gallium Aluminum Arsenide (GaAIAs) laser diodes delivering a total output power of 90 mW Wavelengths 808 nm 830 nm Interaction with the patient Luminous energy absorption Luminous energy absorption The indication for use (IFU) statements of the subject and the predicate devices are identical. The subject and the predicate devices are non-heating infrared laser as defined in 21 CFR 890.5500. Both the subject and the predicate devices use diode lasers to emit photonic energy to tissue. The differences between the subject device and predicate are explained below: Optical power: According to 60601-2-22 Edition 3.1 2012-10 (Recognition Number 12-268), a tolerance of 20% is accepted, justifying the difference between the subject (100 mW) and the predicate (90 mW) devices. Wavelength: The absorption coefficient of laser light by melanin, hemoglobin and water at wavelengths 808 and 830 nm are similar. Non-clinical Performance Testing The following nonclinical performance testing was conducted to demonstrate substantial equivalence.

• IEC 60825-1 Edition 2.0 2007-03 - Safety of laser products - Part 1: Equipment classification, and requirements

• IEC 60601-1 - Edition 3.2 2020-08 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements

• IEC 60601-2-22: 2019 - Edition 4.0 2019-11 Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment

• IEC 62304:2006+AMD1:2015 - Edition 1.1 2015-06 Medical device software - Software life cycle processes

• ISO 10993-1 - Fifth edition 2018-08 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process Clinical Testing Substantial equivalence of the subject device to the predicate has been established through the results of nonclinical testing.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。