Dukal SMS Sterilization Wrap

Dukal, LLC

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEMarch 22, 2024PRODUCT CODEFRG

Indications for use

The Dukal SMS Sterilization Wraps are intended to be used to enclose another medical device that is to be sterilized by a healthcare provider using:

• In a steam sterilization pre-vacuum cycle at 270˚F / 132˚C for 4 minutes o Models 100, 200 and 300 were validated for dry times of 20 minutes; models 400, 500 and 600 were validated for dry times of 30 minutes.

• In 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131˚F / 55˚C and 40-80% relative humidity for 60 minutes. o The wrap was validated for aeration times for EO sterilization of 16 hours at 40.0˚C. Dukal SM S sterilization wraps are intended to allow sterilization of the enclosed medical device(s), and also to maintain sterility of the enclosed device(s) for 6 months or until opened. The d evices are intended for over-the- counter use and are single use disposable sterilization wraps. Test r esults validated that the Dukal SMS sterilization wraps allowed sterilization of the enclosed medical device(s) by ethylene oxide sterilization and by pre-vacuum cycles. These models of the Dukal SMS sterilization wrap have been validated for use with the ethylene oxide and pre-vacuum cycles listed in below table: Du kal SMS Sterilization Wrap Recommendations for Use with the Pre-Vacuum Steam or Ethylene Oxide1 Dukal SMS Sterilization Wrap Models Intended Loads Maximum Wrapped Package Content Weights Used in Sterility Maintenance Validation Study2 Descriptions of Loads Used in Sterility Maintenance Validation Study2 Model 100 Very Light Weight Package (for example: towel packs or batteries) 3 lbs. Pre-Vacuum Steam and EO: 20 huck towels (17”x26”) Model 200 Light Weight Package (for example: standard linen packs or telescope with light cord) 6lbs. Pre-Vacuum Steam and EO: 2 huck towels (17”x26”) 2 fluid resistant U-drapes (68”x109”) 1 fluid resistant universal bar drape (70”x108”) Model 300 Light to Moderate Weight Package (for example: general use medical instruments) 9 lbs. Pre-Vacuum Steam: 15 huck towels (17”x26”) 1 small fluid resistant drape (60”x76”) 5 lbs. of metal mass EO: 16 huck towels 2 fluid resistant large drapes (76”x 100”) 1 fluid resistant small drape (76”x60”) 1 fluid resistant table cover (60” x 90”) Model 4003 Moderate to Heavy Weight Package (for example: general use medical instruments) 13 lbs. Pre-Vacuum Steam and EO: 4 tray liners 20”x25” stacked 10”x10”x2 1/2” tray containing 11 lbs. of metal mass Model 5003 Heavyweight Package (for example: general use medical instruments) 17 lbs. Pre-Vacuum Steam and EO: 4 tray liners 20”x25” stacked 10”x10”x2 1/2” tray containing 15 lbs. of metal mass Model 6003 Very Heavy Weight Package (for example: general use medical instruments) 25 lbs. Pre-Vacuum Steam and EO: 4 tray liners 20”x25” stacked 10”x10”x2 1/2” tray containing 23 lbs. of metal mass 1 Individual results may differ due to factors such as variations in handling practices, wrapping techniques, and folding methods. Results may also differ due to the use of irregularly shaped contents, which may put added stress on the wrap. Each healthcare facility should determine for itself which wrap model is most appropriate for each intended use. 2 It is recommended to not exceed the maximum wrapped package content weights indicated for each wrap model. Furthermore, it is recommended to not exceed the number, weight, and size of individual content types that were validated for the Sterilization Wraps (i.e.: the number and size of the fluid resistant linens or the weight of the metal mass). 3 The 400, 500 and 600 model wraps were validated for sterilant penetration with 3 lbs. of non-fluid resistant linen, and it is recommended to not exceed 3 lbs. of non-fluid resistant linen in sterilization cycles with these models. It is recommended that the user not include fluid-resistant linens in 400, 500 and 600 model wraps, as use of such fluid resistant materials has not been evaluated with these models. Note: The loads used in each Sterility Validation Study corresponded to the maximum wrapped package content weights in above table. Note: The trays used for the pre-vacuum studies were not the same as those used for the EO validation. Therefore, different amounts of metal mass were used in each study to achieve the maximum recommended wrapped package content weights for each wrap model.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 17, 2026