RARA CRAFT DATABASE for FDA Medical Devices
510(k)K233668

FDA DEVICE FACTS

Auryon Atherectomy Catheter 1.5 mm XL, Hydrophilic Coating (EXM-4010-H000), Auryon Atherectomy Catheter 0.9 mm XL, Hydrophilic Coating (EXM-4011-H000), Auryon Atherectomy Catheter 1.5 mm XL (EXM -4010-0000), Auryon Atherectomy Catheter 0.9 mm XL (EXM-4011-0000)

Eximo Medical, Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 15, 2023PRODUCT CODEMCW

Indications for use

The Auryon™ Atherectomy System and Auryon Atherectomy Catheters with aspiration are indicated for use as atherectomy devices for arterial stenoses, including in-stent restenosis (ISR), and to aspirate thrombus adjacent to stenoses in native and stented infra-inguinal arteries. The Auryon™ Atherectomy System and Auryon Atherectomy Catheters without aspiration are indicated for use in the treatment, including atherectomy, of infra-inguinal stenoses and occlusions. The Auryon™ Atherectomy System and Auryon Atherectomy Catheters with aspiration are indicated for use as atherectomy devices for arterial stenoses, including in-stent restenosis (ISR), and to aspirate thrombus adjacent to stenoses in native and stented infra-inguinal arteries. The Auryon™ Atherectomy System and Auryon Atherectomy Catheters without aspiration are indicated for use in the treatment, including atherectomy, of infra-inguinal stenoses and occlusions. Regulation Number 21 CFR §870.4875 21 CFR §870.4875 Regulatory Class Class II Class II Product Code MCW MCW Active Medium Nd:YAG Nd:YAG Laser Wavelength 355 nm 355 nm Laser Fluence levels 50 and 60 mJ/mm2 50 and 60 mJ/mm2 Pulse Rate 40 Hz 40 Hz Pulse Duration 10-25 ns 10-25 ns Maximum output 33.5 mJ 33.5 mJ Catheter sizes 0.9mm, 1.5 mm, 2.0mm, 2.35mm, 0.9mm XL, 1.5mm XL 0.9mm, 1.5 mm, 2.0mm, 2.35mm Platinum/Iridium marker band Included in 0.9 mm and 0.9mm XL catheters only Included in 0.9 mm catheter only Catheter Sterilization Method Ethylene Oxide Ethylene Oxide Comparison of Performance Data The new 0.9 mm XL and 1.5 mm XL Auryon Atherectomy System devices were tested using the same methods and acceptance criteria as was done in the predicate device 510(k). The specific tests are listed below

Summary of Performance Testing

• Catheter shaft ID, OD, and working length

• Catheter trackability in simulated anatomical shape

• Optical Functionality test

• Catheter torque test

• Catheter optical durability

• Validation that the longer catheters can be sterilized in the predicate device sterilization process o B&F testing o Bioburden recovery rate o Bioburden determination o Comparison of natural product resistance to Biological Indicators o EO Residuals o LAL testing

See the full product information製品情報をすべて見るには