Meta+ Bone Cement & M.U.S.T. Fenestrated Pedicle Screw System

Medacta International S.A.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJune 12, 2024PRODUCT CODEPML

Indications for use

+ M.U.S.T. Fenestrated Pedicle Screw The M.U.S.T. Fenestrated Pedicle Screw System when used without cement is intended for posterior non-cervical pedicle fixation (T1-S2/ilium) or anterolateral fixation (T8-L5). These devices are indicated as an adjunct to fusion for all of the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis, and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion in skeletally mature patients. When used in conjunction with Metat+ Spine cement, the M.U.S.T. Fenestrated Pedicle Screw System is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the thoracic and lumbar spine, in whom life expectancy is of insufficient duration to allow for achievement of fusion. M.U.S.T. Fenestrated Pedicle Screw System augmented with Meta+ Spine cement is intended for use at spinal levels where the structural integrity of the spine is not severely compromised. * Meta+ Spine Cement Meta+ Spine cement, when used in conjunction with the M.U.S.T. Fenestrated Pedicle Screw System, is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the thoracic and lumbar spine, in whom life expectancy is of insufficient duration to allow for achievement of fusion. The M.U.S.T. Fenestrated Pedicle Screw System, augmented with Meta+ Spine Cement, is for use at spinal levels where the structural integrity of the spine is not severely compromised.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 17, 2026