510(k)K241952

FDA DEVICE FACTS

AQUABEAM Robotic System (AB2000)

Procept Biorobotics

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATESeptember 30, 2024PRODUCT CODEPZP

Indications for use

The AQUABEAM Robotic System is intended for the resection and removal of prostate tissue in males suffering from lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia. The intended use of the subject device is identical to the intended use of the predicate device. Intended Patient Population The intended patient population is males suffering from LUTS resulting from benign prostatic hyperplasia (BPH). Technological Comparison as compared to the Predicate Device This 510K is submitted for introduction of the new software and version for AQUABEAM Robotic System. All the other technological characteristics of the device are identical to the predicate device. The table below compares the predicate device and the subject device for the comparison – Device Characteristic Subject Device Predicate Device Software SW0021-282 The software shall limit the user from planning a cut in profile path beyond the depth of the cut defined in the angle step for mid prostate and bladder neck. Since the user is now limited to exceed the depth defined, the purple line indicator flashing is removed. The median lobe depth of cut is not limited. SW0021-281 The user has the option to exceed the depth for bladder neck, mid-prostate, and median lobe. The purple lines on the GUI blink when the depth is exceeded. The maximum depth constraint is removed from the Profile Landmark The maximum depth constraint could not let the PROCEPT BioRobotics Corporation · 150 Baytech Drive · San Jose, CA 95134 office: +1.650.232.7200 · info@PROCEPT-BioRobotics.com step. The user is able to place the 4 landmark points beyond the 24.3 mm depth. The maximum depth the user can plan still is in 24.3mm user place the markers beyond the 24.3mm.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 16, 2026