Aesculap Aicon® Series Container System

Aesculap, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEMay 13, 2025PRODUCT CODEKCT

Indications for use

The AESCULAP Aicon® Container is a reusable rigid sterilization container intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device during transport and until used. This container is compatible for use in the following sterilization modalities in the configurations listed below:

• E thylene Oxide (EtO)

• ST ERIS V-PRO maX/maX 2: Lumen, Non-Lumen, Flex

• ST ERIS V-PRO 60: Lumen, Non- Lumen, Flex STERIS V-PRO S2 Non-Lumen

• S TERRAD 100NX: Standard, Express, Flex, Duo

• S TERRAD NX: Standard, Advanced

• ST ERRAD 100S

• ST ERIZONE VP4

• P reVac Steam The AESCULAP Aicon® consists of two different container styles: a solid bottom container and enhance drying system (EDS) container. T he AESCULAP Aicon® Container is compatible with accessories such as baskets, trays, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders, and tags. Prevac cycles without dry times are Immediate Use Sterilization Cycles (IUSS). The fol lowing tables identify the load configurations. T able 1. AESCULAP Aicon® Container Lumen Configurations IOS Configuration Container Sizes Compatible Lumens Ethylene Oxide (EtO) (130°F, 60 minute exposure 50-70% RH, concentration 735mg/L) If including silicone, stainless steel, or no IOS: Full Size (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) Three-Quarter Size (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) Half Size (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) STERIS V-PRO maX /maX 2 Lumen Cycle Only stainless steel or no IOS: Full Size (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) Three-Quarter Size (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) Half Size (12) Stainless Steel Lumens (≥1mm ID x ≤ 150mm L) STERIS V-PRO Max/ Max 2 Non-Lumen Cycle If including silicone, stainless steel, or no IOS: Full Size Non lumened stainless steel instruments Three-Quarter Size Non lumened stainless steel instruments Half Size Non lumened stainless steel instruments STERIS V-PRO maX / maX 2 Flex Cycle Only stainless steel or no IOS: Full Size (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: September 1, 2026