RARA CRAFT DATABASE for FDA Medical Devices
510(k)K251184

FDA DEVICE FACTS

AltiVate Reverse Shoulder System; RSP Shoulder System; SMR Shoulder System; PRIMA Humeral System; PRIMA Glenoid System

Encore Medical L.P.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEMay 16, 2025PRODUCT CODEPHX

Indications for use

AltiVate Reverse® Shoulder System: Indications for RSP® Modular Stem: The Reverse® Shoulder Prosthesis (RSP®) Humeral Stem and Socket Shell are indicated for use in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly rotator cuff deficient shoulder joint. The patient’s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The humeral stem is intended for cemented use only. Indications for RSP ® Monoblock Stem: The Reverse® Shoulder Prosthesis Monoblock is indicated for patients with a functional deltoid muscle with a grossly deficient rotator cuff shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly deficient rotator cuff shoulder joint:

• In cases of fracture of glenohumeral joint from trauma or pathologic conditions of the shoulder, including humeral head fracture or displaced 3- or 4-part fractures of proximal humerus.

• In cases of bone defect in proximal humerus. The patient’s joint must be anatomically and structurally suited to receive the selected implant(s). The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The humeral stem is intended for cemented or Cementless use (Cementless use not cleared in the EU). Indications for AltiVate Reverse ® Humeral Stem and Small Shell Humeral Stem (Primary, Short Stem and Revision) Reverse Total Shoulder Indications: The AltiVate Reverse® Shoulder Prosthesis is indicated as a reverse shoulder replacement for patients with a functional deltoid muscle and a grossly deficient rotator cuff joint suffering from pain and dysfunction due to:

• Severe arthropathy with a grossly deficient rotator cuff;

• Previously failed joint replacement with a grossly deficient rotator cuff;

• Fracture of glenohumeral joint from trauma or pathologic conditions of the shoulder including humeral head fracture, displaced 3- or 4-part fractures of proximal humerus, or reconstruction after tumor resection;

• Bone defect in proximal humerus;

• Non-inflammatory degenerative disease including osteoarthritis and avascular necrosis of the natural humeral head and/or glenoid;

• Inflammatory arthritis including rheumatoid arthritis;

• Correction of functional deformity. The glenoid baseplate is intended for cementless application with addition of screws for fixation. This device may also be indicated in the salvage of previously failed surgical attempts for anatomic and hemi procedures. All RSP® Monoblock and AltiVate Reverse® humeral stems are intended for cemented or cementless use. SMR Shoulder System: The SMR Shoulder System is intended for partial or total, primary or revision shoulder joint replacement. The SMR Anatomic Shoulder System is indicated for partial or total, primary or revision shoulder joint replacement in patients suffering from disability due to:

• non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis;

• inflammatory degenerative joint disease such as rheumatoid arthritis;

• treatment of acute fractures of the humeral head that cannot be treated with other fracture fixation methods;

• revision of a failed primary implant; in case of SMR Short Stems only if sufficient bone stock remains);

• cuff tear arthropathy (CTA Heads only);

• glenoid arthrosis without excessive glenoid bone loss: A1, A2 and B1 according to Walch classification (SMR TT Hybrid Glenoid only). The SMR Reverse Shoulder System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff deficient joint with severe arthropathy (disabled shoulder). The patient’s joint must be anatomically and structurally suite d to receive the selected implants and a functional deltoid muscle is neces sary to use the device. The SMR TT Hybrid Glenoid Reverse Baseplate must not be used in cases of excessive glenoid bone loss and/or when bone graft is needed. The Modular SMR Shoulder System allows the assembly of components in various hu meral and glenoid constructs. The constructs are intended for cemented and uncemented use as specified in the following table. In the Anatomic shoulder the humeral construct consists of the humeral stem, the humeral body, the adaptor taper and the humeral head. In the Reverse shoulder the humeral construct consists of the humeral stem, the reverse humeral body and the reverse liner. On the humeral side the fixation of the humeral stem determines if the construct is cemented or uncemented. The Anatomic glenoid construct consists of an all polyethylene glenoid, a polyethylene glenoid with metal peg or a metal back assembled with a liner; the Reverse glenoid consists of a metal back/connector/glenosphere construct or of a peg/baseplate/glenosphere construct. On the glenoid side, the fixation of all polyethylene glenoid, the polyethylene glenoid with metal peg or the metal back determines if the construct is cemented or uncemented. System Components Material System Use A R Cem Not Cem

• • SMR Stem (Cemented, Cemented Revision) Ti6Al4V X

• • SMR Stem (Cementless Finned, Cementless Revision) Ti6Al4V X

• • SMR Short Stem (Cementless Finned) Ti6Al4V X

• SMR Humeral Body (Trauma, Finned) Ti6Al4V X X

• • SMR Reverse Humeral Body Ti6Al4V X X

• • Humeral Extension Ti6Al4V X X

• SMR Humeral Head (Standard*, CTA) CoCrMo X X

• SMR Adaptor Taper (Neutral, Eccentric) Ti6Al4V X X System Components Material System Use A R Cem Not Cem

• SMR CTA Head Adaptor for Reverse Humeral Body Ti6Al4V X X

• SMR Glenosphere* CoCrMo X

• SMR Connector* Ti6Al4V X

• Reverse Liner UHMWPE X X LimaVit (Vitamin E highly crosslinked UHMWPE) X X

• SMR Cemented Glenoid UHMWPE X

• SMR 3 Pegs Cemented Glenoid UHMWPE X

• • * SMR TT Hybrid Glenoid UHMWPE+ Ti6Al4V 3D printed +Ta X X

• SMR TT Hybrid Glenoid Reverse Baseplate + Screw Ti6Al4V X

• • SMR Metal Back Glenoid Ti6Al4V+PoroTi X* X*

• • SMR TT Baseplate Ti6Al4V X* X*

• SMR TT Augmented 360 Baseplate Ti6Al4V X

• • SMR TT Glenoid Peg Ti6Al4V 3D printed X X

• SMR Metal Back Liner UHMWPE X* X*

• * • SMR Bone screw Ti6Al4V X Material Standards Ti6Al4V (ISO 5832-3 - ASTM F1472) – Ti6Al4V 3D printed (to meet the mechanical and chemical requirements of ISO 5832-3) - CoCrMo (ISO 5832-12 - ASTM F1537) – UHMWPE (ISO 5834-2 - ASTM F648) - LimaVit (Vitamin E highly crosslinked UHMWPE) (ISO 5834-2 - ASTM F648 - ASTM F2695 – ASTM F2565) - PoroTi Titanium Coating (ASTM F1580) - Ta (ISO13782 - ASTM F560) A= Anatomic / R=Reverse *NOTE:

• When considering the humeral side, SMR Glenosphere Ø42 can be coupled only with PRIMA Humeral System.

• In the US, the SMR Metal Backed Glenoid/Liner construct, used as part of the SMR Anatomic Shoulder Replacement, is intended for use with bone cement and should be used without bone screws.

• The SMR Metal Backed Glenoid/Connector/Glenosphere construct, used as part of the SMR Reverse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.

• SMR Lateralized Connectors are not indicated for use with glenoid bone grafting techniques.

• In the US the SMR TT Metal Back Baseplate used as part of the SMR Anatomic Shoulder Replacement, is intended for use with bone cement and should be used without bone screws; while when used as part of the SMR Reverse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.

• If a SMR TT Hybrid Glenoid is in place and revision to a reverse prosthesis is required, the patient can be revised by removing the polyethylene baseplate, leaving the metal peg in place and by connecting it to the SMR TT Hybrid Glenoid Reverse Baseplate. The SMR TT Hybrid Glenoid Reverse Baseplate is intended for uncemented use with the addition of screws for fixation.

• The Dia. 50, 52 and 54mm Humeral Heads with + 3mm increased height cannot be coupled to the Long Adaptor Tapers (both concentric and eccentric). The Dia. 52 and 54mm Humeral Heads with + 2mm increased height cannot be coupled to the Long Adaptor Tapers (both concentric and eccentric).

• The SMR Reverse Humeral System is compatible with the RSP® Glenoid and AltiVate Reverse® Glenoid systems only when a diameter 36 or 40mm SMR Reverse Insert LimaVit are used. Instructions for use of the Enovis Reverse Shoulder System should be consulted prior to use.

• The SMR Reverse Glenoid System is compatible with the RSP® Humeral and AltiVate Reverse® Humeral systems only when a diameter 36 or 40mm SMR Glenosphere are used. Instructions for use of the Enovis Reverse Shoulder System should be consulted prior to use. PRIMA Shoulder System: PRIMA Humeral System The PRIMA Humeral System is intended for partial or total, primary or revision, shoulder joint replacement in skeletally mature patients. The patient's joint must be anatomically and structurally suited to receive the selected implants and a functional del toid muscle is necessary to use the device. The PRIMA Short Stem and PRIMA Short Stem Plus are intended for use in cementless and cemented applications, at the discretion of the surgeon. The PRIMA Anatomic implant is indicated for partial or total, primary or revision shoulder joint replacement, in patients suffering from pain and disability due to:

• Non-inflammatory degenerative joint disease (i.e. osteoarthritis),

• Inflammatory arthritis of the glenohumeral join including rheumatoid arthritis,

• Avascular necrosis of the humeral head,

• Traumatic/post-traumatic arthritis,

• Fractures of the humeral head where adequate fixation can be achieved and adequate bone stock remains,

• Post-fracture deformity with intact rotator cuff, where adequate fixation can be achieved and adequate bone stock remains,

• Cuff tear arthropathy (CTA Heads only). The PRIMA Reverse implant is indicated for primary reverse total shoulder replacement or for revision when converting an anatomic PRIMA arthroplasty to a reverse total shoulder arthroplasty (i.e. in case of cuff tear arthropathy or in a grossly rotator cuff deficiency joint with severe arthropathy). Revision surgery with retention of the PRIMA Short Stem and PRIMA Short Stem Plus are intended as conversion surgery from anatomic to reverse, where the stem is stable, well positioned and tissue integrated. Other revisions of the humeral prosthesis part should be treated with traditional shoulder prostheses. The PRIMA reverse implant is indicated for patients suffering from pain and disability due to:

• Rotator cuff tear arthropathy,

• Osteoarthritis with rotator cuff tear,

• Rheumatoid arthritis with rotator cuff tear,

• Massive irreparable rotator cuff tear,

• Avascular necrosis of the humeral head,

• Correction of functional deformity, where adequate fixation can be achieved and adequate bone stock remains,

• Fractures of the humeral head where adequate fixation can be achieved and adequate bone stock remains. The PRIMA Humeral System consists of the following single use components:

• Anatomic configuration:

- stem

- adaptor for humeral heads.

• Reverse configuration:

- stem

- reverse tray

- reverse insert. System Components Material A R   PRIMA Short Stem Ti6Al4V 3d printed   PRIMA Short Stem Plus Ti6Al4V 3d printed  PRIMA Adaptor with screw Ti6Al4V  PRIMA Reverse Tray Ti6Al4V  PRIMA Reverse Insert LimaVit (Vitamin E highly crosslinked UHMWPE), Ti6Al4V Material Standards Ti6Al4V (ISO 5832-3 - ASTM F1472), Ti6Al4V 3d printed (ISO 5832-3), LimaVit (Vitamin E highly crosslinked UHMWPE) (ISO 5834-2 - ASTM F648 - ASTM F2695 – ASTM F2565) A = Anatomic, R = Reverse Table 1 PRIMA Humeral System components materials The PRIMA Humeral System is intended to be used with all glenoids implants belonging to the SMR Shoulder System and PRIMA Glenoid System. The PRIMA Humeral System is compatible with the RSP® Glenoid and AltiVate Reverse® Glenoid systems only when a diameter 36 or 40mm PRIMA Reverse Insert LimaVit are used. Instructions for use of the Enovis Reverse Shoulder System should be consulted prior to use. PRIMA Glenoid System The PRIMA Glenoid System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff deficient joint with severe arthropathy (disabled shoulder). The patient’s joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to us e the device. The PRIMA Glenoid System components are intended for uncemented use with the addition of screw fixation.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: September 1, 2026