RARA CRAFT DATABASE for FDA Medical Devices
510(k)K251987

FDA DEVICE FACTS

Rapid Aortic Measurements

Ischemaview, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

AI/ML
DECISION DATESeptember 23, 2025PRODUCT CODEQIHCLINICAL AREARadiology

Indications for use

Rapid Aortic Measurements (AM) is an image analysis and measurement device to evaluate aortic and iliac arteries in contrast enhanced and non-contrast CT imaging datasets acquired of the chest, abdomen, and/or pelvis. The module segments the aorta, iliacs, and major branching vessels and provides 2D and 3D visualizations of the segmented vessels. Outputs of the device include: Centerline measurements of the aorta and iliacs, Aortic Zone Measurements (Maximum Oblique Diameter), Fixed Measurements of the aorta and left and right iliacs, 3D Volume Renderings, Rotations, Curved Planar Reformations (CPRs) of the isolated left and right iliacs, aortic oblique Multiplanar Reconstructions (MPRs), and Longitudinal Tracking visualizations. Rapid Aortic Measurements is an aid to physician decision making. Its results are not intended to be used on a stand-alone basis for clinical decision-making or otherwise preclude clinical assessment. Rapid Aortic Measurements is indicated for adults. Precautions/Exclusions:

- Series containing excessive patient motion or metal implants may impact module output quality.

- The AM module will not process series that meet the following module exclusion criteria: series acquired with cone-beam CT scanners (c-arm CT); series that are non-axial or axial oblique greater than 5 degrees; series containing improperly ordered or missing slices where the gap is larger than 3 times the median inter-slice distance (e.g., as a result of manual correction by an imaging technician); series with less than 3 cm of target anatomical zones (e.g., aorta or right/left iliac artery); or NCCT, CECT, CTA, or CTPA datasets with in-plane X and Y FOV < 160 mm, Z FOV (cranio-caudal transverse anatomical coverage) < 144 mm, in-plane pixel spacing (X & Y resolution) < 0.3 mm or > 1.0 mm, inter-slice distance < 0.3 mm or > 3 mm, slice thickness > 3 mm, or data acquired at x-ray tube voltage < 70 kVp or > 150 kVp, including single energy, dual energy, or virtual monochromatic datasets.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン