RARA CRAFT DATABASE for FDA Medical Devices
510(k)K252373

FDA DEVICE FACTS

BioFlo Hybrid PICC with ENDEXO Technology and PASV Valve Technology; BioFlo PICC with ENDEXO Technology and PASV Valve Technology; BioFlo PICC with ENDEXO Technology; BioFlo Midline Catheter; Xcela Power Injectable PICC; Xcela PICC with PASV Valve Technology; Xcela Hybrid PICC with PASV Valve Technology

Spectrum Vascular

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 16, 2025PRODUCT CODELJS

Indications for use

BioFlo Hybrid PICC with ENDEXO Technology and PASV Valve Technology The BioFlo Hybrid PICC with ENDEXO and PASV Valve Technology is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients; the sampling of blood; and for power injection of contrast media. Non-valved lumens are indicated for central venous pressure monitoring. 6F catheter is indicated for patients weighing >10 kg. Maximum Power Injection Flow Rate:

• 6F Triple Lumen / 55 cm - 6 mL/sec BioFlo PICC with ENDEXO and PASV Valve Technology The BioFlo PICC with ENDEXO and PASV Valve Technology is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients; the sampling of blood; and for power injection of contrast media. 6F catheter is indicated for patients weighing >10 kg. Maximum Power Injection Flow Rate:

• 3F Single Lumen/55 cm - 1 mL/sec

• 4F Single Lumen/55 cm - 3.5 mL/sec

• 5F Single Lumen/55 cm - 5 mL/sec

• 5F Dual Lumen/55 cm - 4 mL/sec

• 6F Dual Lumen/55 cm - 5 mL/sec

• 6F Triple Lumen/55 cm - 6 mL/sec BioFlo PICC with ENDEXO Technology The BioFlo PICC with ENDEXO Technology is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications, nutrients; the sampling of blood; for central venous pressure monitoring and for power injection of contrast media. 6F catheter is indicated for patients weighing >10 kg. Maximum Power Injection Flow Rate:

• 3F Single Lumen/55 cm - 1 mL/sec

• 4F Single Lumen/55 cm - 3.5 mL/sec

• 5F Single Lumen/55 cm - 5 mL/sec

• 5F Dual Lumen/55 cm - 4 mL/sec

• 6F Dual Lumen/55 cm - 5 mL/sec

• 6F Triple Lumen/55 cm - 6 mL/sec BioFlo Midline Catheter The BioFlo Midline Catheter is indicated for short term access (< 30 days) to the peripheral venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and the sampling of blood and blood products. Maximum Power Injection Flow Rate:

• 3F Single Lumen/20 cm - 2 mL/sec

• 4F Single Lumen/20 cm - 6 mL/sec

• 5F Single Lumen/20 cm - 6 mL/sec

• 5F Dual Lumen/20 cm - 6 mL/sec Xcela Power Injectable PICC The Xcela Power Injectable PICC is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients; the sampling of blood; and for power injection of contrast media. 6F catheter is indicated for patients weighing >10 kg. Maximum Power Injection Flow Rate:

• 4F Single Lumen/45 cm - 4 mL/sec

• 4F Single Lumen/55 cm - 3.5 mL/sec

• 5F Single Lumen/55 cm - 5 mL/sec

• 5F Dual Lumen/45 cm - 5 mL/sec

• 5F Dual Lumen/55 cm - 4 mL/sec

• 6F Dual Lumen/55 cm - 5 mL/sec Xcela PICC with PASV Valve Technology The Xcela PICC with PASV Valve Technology is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients; the sampling of blood; and for power injection of contrast media. 6F catheter is indicated for patients weighing >10 kg. Xcela Hybrid PICC with PASV Technology The Xcela Hybrid PICC with PASV Valve Technology is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications and nutrients; the sampling of blood; and for power injection of contrast media. Non-valved lumens are indicated for central venous pressure monitoring. 6F catheter is indicated for patients weighing >10 kg. Maximum Power Injection Flow Rate:

• 6F Triple Lumen/55 cm - 6 mL/sec

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。