FDA DEVICE FACTS
Triever Duo Catheter
Inari Medical, Inc.
Verified FDA Record identity for medical-device development research. This overview uses only fields stated in the FDA Record and is not a Device Description.医療機器開発の調査用に、確認済みの FDA Record の識別情報を示しています。この概要は FDA Record に記載された項目だけによるもので、機器説明ではありません。
Indications for use
The FlowTriever Retrieval/Aspiration System is indicated for:
• The non-surgical removal of emboli and thrombi from blood vessels.
• Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel.
The FlowTriever Retrieval/Aspiration System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism.
The Triever Duo, a Triever Catheter within the FlowTriever Retrieval/Aspiration System, is indicated for:
• Treating clot in transit in the right atrium, but not in conjunction with FlowTriever Catheters.
• Pressure Measurement.
| Subject Device Triever Duo Catheter | Primary Predicate Device Triever24 Catheter | Reference Device Langston Dual Lumen Catheter | |
|---|---|---|---|
| 510(k) Number | K253419 | K213402 | K221470 |
| Manufacturer | Inari Medical, Inc. | Inari Medical, Inc. | Vascular Solutions, LLC. |
| Regulations | 21 CFR 870.5150 Embolectomy Catheter | 21 CFR 870.5150 Embolectomy Catheter | 21 CFR 870.1200 Diagnostic Intravascular Catheter |
| Product Code | QEW, KRA, DQO | QEW, KRA | DQO |
| Intended Use/ Indicationsfor Use | The FlowTriever Retrieval/Aspiration System is indicated for: • The non-surgical removal of emboli and thrombi from blood vessels. • Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The FlowTriever Retrieval/Aspiration System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. The Triever Duo, a Triever Catheter within the FlowTriever Retrieval/Aspiration System, is indicated for: • Treating clot in transit | FlowTriever Retrieval/Aspiration System is indicated for: • The non-surgical removal of emboli and thrombi from blood vessels. • Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The FlowTriever Retrieval/Aspiration System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. Triever Catheters are also intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever Catheters. | Each Langston dual lumen catheter is indicated for delivery of contrast medium in angiographic studies and for simultaneous pressure measurement from two sites. This type of pressure measurement is useful in determining transvalvular, intravascular and intraventricular pressure gradients. |
Tables marked from the FDA document were reconstructed automatically. Check the original FDA document (links at the end of this page) for authoritative values.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。