FDA DEVICE FACTS
Infinity® Acute Care System (IACS) VG8.1
Draeger Medical Systems, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
(IACS, M540) Similar to predicate. Removal of the Apnea indication and addition of “Non-invasive” to the SpO2 indication have no impact on Intended Use or Indications for Use relative to supporting data. Similar Cybersecurity Enhancements Enhancements to packet storm mitigation Data-in-transit, Password security New Operating System VG8.1 uses a hardened Windows 10 IoT Enterprise LTSC, versus Windows XP Embedded in the predicate. Similar Patching / Hotfixes VG8.1 supports Windows 10 and Edge patches/hotfixes New SpO2 Alarms VG8.1 makes the desaturation alarm always enabled (ON) for all patient populations and adds new low-priority advisory alarm messages for SpO2 sensor/cable status (predicate: desaturation alarm conditional, neonates only). Configurable SpO2 sensor-off/check-sensor alarm priority is unchanged; the changes are informational and do not affect core SpO2 measurement performance. Similar Dual SpO2 Monitoring VG8.1 introduces dual SpO2 monitoring via a secondary SpO2 source connected to the Cockpit through an RS-232 interface (not supported in predicate). The IACS acts as a display-only interface for the secondary data and does not generate or annunciate alarms for the external SpO2 device. New M540 Respiration Monitoring VG8.1 removes Manual Mode (Auto Mode unchanged). Detection threshold, measurement range, and resolution for Auto Mode are identical to predicate. Respiration accuracy presentation was revised from a mixed bpm/% format to a bpm-only format Similar CO2 Monitoring – Mainstream Compatibility VG8.1 remains compatible with MCable Mainstream CO2 variant 6871950 (K100941) and introduces compatibility with the Infinity MCable Mainstream CO2 variant 6873570 (K221118), due to future obsolescence of the 6871950 variant. Similar CO2 Monitoring – Infinity MCable Mainstream CO2 variant (6871950) The IACS makes no modification to this sensor. It displays the measurement output without analysis or modification, with identical claims (intended use, indications, intended population, environment of use) to the cleared sensor (K100941). The IACS compatibility with this sensor remains the same as with the predicate (IACS VG4.2, K203088). Same CO2 Monitoring – Infinity MCable Mainstream CO2 variant (6873570) The IACS makes no modification to this sensor. It displays the measurement output without analysis or modification, with identical claims (intended use, indications, intended population, environment of use) to the cleared sensor (K221118). New CO2 Monitoring – Infinity MCable Microstream Compatibility New in VG8.1: compatibility with the Infinity MCable Microstream CO2 (Oridion device without Draeger branding, cleared under K094012) for intubated and non-intubated patients, adults, pediatrics, and neonates. New CO2 MCable Respiratory – Measuring Method/ Range/Accuracy (Mainstream variants) Measuring method, range, and accuracy identical to predicate for both mainstream CO2 variants. Same CO2 MCable Respiratory – Measuring Method/Range (Microstream) New measuring method introduced with the Microstream accessory: sidestream infrared absorption spectroscopy; measuring range (etCO2/inCO2) 0–99 mmHg; respiratory rate range 0–150 bpm; respiratory rate accuracy +/-1 bpm (0–70 bpm), +/-2 bpm (71–120 bpm), +/-3 bpm (121–150 bpm). Uses the same measuring method and range as the Medtronic MicroMediCO2 module. New Parameter Display – Mainstream CO2 variants Parameters (etCO2, inCO2, RRc) identical to predicate. Same Parameter Display – Microstream CO2 New parameters displayed via Microstream accessory: etCO2, inCO2, RRc — same parameters as the Medtronic MicroMediCO2 module. New Reprocessing Reprocessing information updated for the M540 and M500 Docking Station, including IFU formatting changes and updated disinfectant information, since predicate clearance (K203088). Similar Biocompatibility Unaffected by the changes, same as predicate. Same Sterility / Shelf-Life Unaffected by the changes, same as predicate. Same Substantial Equivalence Summary Operational and technological characteristics form the basis for the determination of substantial equivalence of the subject device with the legally marketed predicate device (K203088). The proposed modifications do not change the fundamental scientific technology of the cleared device. The subject device is substantially equivalent to the predicate device.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。