AMSCO 700 Steam Sterilizer

STERIS Corporation

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJune 24, 2026PRODUCT CODEFLECLINICAL AREAPatient Monitoring

Indications for use

The AMSCO 700 Steam Sterilizers are designed for sterilization of heat- and moisture-stable materials used in healthcare facilities and are equipped with the following factory-programmed cycles: * Prevac: 270°F (132°C), 4-minute sterilization, 20-minute drying; fabric packs, subject to the recommended quantities below. * Prevac: 270°F (132°C), 4-minute sterilization, 30-minute drying; double-wrapped instrument trays weighing no more than 25 lb (11.3 kg) each and fabric packs, subject to the maximum quantities below. * Prevac: 270°F (132°C), 4-minute sterilization, 5-minute drying; single fabric pack. * Prevac: 275°F (135°C), 3-minute sterilization, 30-minute drying; double-wrapped instrument trays weighing no more than 25 lb (11.3 kg) each, subject to the recommended quantities below. * Prevac: 270°F (132°C), 10-minute sterilization, 30-minute drying; double-wrapped instrument trays weighing no more than 25 lb (11.3 kg) each, subject to the recommended quantities below. * Prevac-IUSS: 270°F (132°C), 4-minute sterilization, 1-minute drying; immediate use of a single unwrapped tray. * Gravity: 270°F (132°C), 15-minute sterilization, 30-minute drying; double-wrapped instrument trays weighing no more than 25 lb (11.3 kg) each, subject to the recommended quantities below. * Gravity: 250°F (121°C), 30-minute sterilization, 30-minute drying; double-wrapped instrument trays weighing no more than 25 lb (11.3 kg) each, subject to the recommended quantities below. * Warm-Up: 270°F (132°C), 3-minute sterilization, 1-minute drying; no load specified. * DART: 270°F (132°C), 3.5-minute sterilization, 1-minute drying; Bowie-Dick Test Pack or DART Test Pack. * Leak Test: temperature, sterilization time, drying time, and load are not applicable. Maximum quantities of wrapped instrument trays and fabric packs by sterilizer size are: * 26 x 26 x 39 inches: 9 wrapped instrument trays or 12 fabric packs. * 26 x 26 x 51 inches: 12 wrapped instrument trays or 16 fabric packs. * 26 x 26 x 63 inches: 15 wrapped instrument trays or 20 fabric packs. The Automated Load and Unload System (ALUS) provides semi-automated loading and unloading from an AMSCO 700 steam sterilizer when a cycle is complete. Alternatively, ALUS may provide automatic unloading only in combination with manual loading. ALUS can start a cycle automatically when equipped with the optional barcode reader.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 16, 2026