Indications for use
Triathlon® Knee System General Total Knee Arthroplasty (TKR) Indications:
• Painful, disabling joint disease of the knee resulting from: noninflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis, or avascular necrosis), rheumatoid arthritis or post-traumatic arthritis.
• Post-traumatic loss of knee joint configuration and function.
• Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability.
• Revision of previous unsuccessful knee replacement or other procedure.
• Fracture of the distal femur and/or proximal tibia that cannot be stabilized by standard fracture -management techniques. The Triathlon® Tritanium® Total Knee System components are indicated for both uncemented and cemented use. The Triathlon® Total Knee System beaded and beaded with Peri-Apatite components are intended for uncemented use only. The Triathlon® All Polyethylene tibial components are indicated for cemented use only. Additional Indications for Posterior Stabilized (PS) and Total Stabilizer (TS) Components:
• Ligamentous instability requiring implant bearing surface geometries with increased constraint.
• Absent or non-functioning posterior cruciate ligament.
• Severe anteroposterior instability of the knee joint. Additional Indications for Total Stabilizer (TS) Components:
• Severe instability of the knee secondary to compromised collateral ligament integrity or function. Indications for Bone Augments:
• Painful, disabling joint disease of the knee secondary to: degenerative arthritis, rheumatoid arthritis, or post-traumatic arthritis, complicated by the presence of bone loss.
• Salvage of previous unsuccessful total knee replacement or other surgical procedure, accompanied by bone loss. Additional Indications for Cone Augments:
• Severe degeneration or trauma requiring extensive resection and replacement
• Femoral and Tibial bone voids
• Metaphyseal reconstruction The Triathlon TS Cone Augment components are intended for cemented or cementless use. Triathlon® Hinge Knee System Triathlon® Hinge Knee System is intended to be implanted with bone cement for the following condition(s):
• There is destruction of the joint surfaces, with or without significant bone deformity.
• The cruciate and/or collateral ligaments do not stabilize the knee joint.
• The ligaments are inadequate and/or the musculature is weak. And/or
• Revision is required of a failed prosthesis where there has been gross instability, with or without bone loss or inadequate soft tissue. When used with MRH femur and/or MRH tibial baseplate replacement indicated in revision of an existing prosthesis:
• Revision is required of a failed prosthesis where there has been gross instability, with or without bone loss or inadequate soft tissue. When used with compatible GMRS components:
• Where segmental resection and/or replacement of femur and/or proximal tibia is required Scorpio ® Total Knee System Indications for the Scorpio-Flex Cruciate Retaining Tibial Insert:
• Painful, disabling joint disease of the knee resulting from: degenerative arthritis, rheumatoid arthritis or post-traumatic arthritis
• Post-traumatic loss of knee joint configuration and function
• Moderate varus, valgus, or flexion deformity in which the ligaments structures can be returned to adequate function and stability
• Revision of previous unsuccessful knee replacement or other procedure Indications for the Scorpio NRG Tibial Bearing Insert – Posteriorly Stabilized Insert: The Scorpio NRG Knee system components are for use in total knee arthroplasty as a result of:
• Painful, disabling joint disease of the knee resulting from degenerative arthritis; rheumatoid arthritis or post-traumatic arthritis
• Post-traumatic loss of knee joint configuration and function
• Moderate varus, valgus, or flexion deformity in which the ligaments structures can be returned to adequate function and stability
• Revision of previous unsuccessful knee replacement or other procedure Additional indications for the Posterior stabilized components include:
• Ligamentous instability requiring implant bearing surface geometries with increased constraint
• Absent or non-functioning posterior cruciate ligament. Indications for the Scorpio-Flex Posterior Stabilized Tibial Insert:
• Painful, disabling joint disease of the knee resulting from degenerative arthritis; rheumatoid arthritis or post-traumatic arthritis
• Post-traumatic loss of knee joint configuration and function; moderate varus, valgus, or flexion deformity in which the ligaments structures can be returned to adequate function and stability
• Revision of previous unsuccessful knee replacement or other procedure
• Ligamentous instability requiring implant bearing surface geometries with increased constraint
• Absent or non-functioning posterior cruciate ligament. Indications for the Scorpio NRG Tibial Bearing Insert – Cruciate Retaining Insert: The Scorpio NRG Knee system components are for use in total knee arthroplasty as a result of
• Painful, disabling joint disease of the knee resulting from degenerative arthritis; rheumatoid arthritis or post-traumatic arthritis
• Post-traumatic loss of knee joint configuration and function
• Moderate varus, valgus, or flexion deformity in which the ligaments structures can be returned to adequate function and stability
• Revision of previous unsuccessful knee replacement or other procedure Additional Indications for Posterior Stabilized Devices:
• Ligamentous instability requiring implant bearing surface geometries with increased constraint
• Absent or non-functioning posterior cruciate ligament. Indications for the Osteonics Scorpio Universal Dome Patella:
• Painful, disabling joint disease of the knee resulting from: degenerative arthritis, rheumatoid arthritis or post-traumatic arthritis
• Post-traumatic loss of knee joint configuration and function
• Moderate varus, valgus, or flexion deformity in which the ligaments structures can be returned to adequate function and stability
• Revision of previous unsuccessful knee replacement or other procedure Indications for the Scorpio Total Stabilizer Insert: General TKR Indications
• Painful, disabling joint disease of the knee resulting from: degenerative arthritis, rheumatoid arthritis or post-traumatic arthritis
• Post-traumatic loss of knee joint configuration and function
• Moderate varus, valgus, or flexion deformity in which the ligaments structures can be returned to adequate function and stability
• Revision of previous unsuccessful knee replacement or other procedure Additional Indications for Posterior Stabilized (PS) or Total Stabilized (TS) Components:
• Ligamentous instability requiring implant bearing surface geometries with increased constraint
• Absent or non-functioning posterior cruciate ligament
• Severe anteroposterior instability of the knee joint
• For Total Stabilizer (TS) Components Only: Severe instability of the knee secondary to compromised collateral ligament integrity or function Indications for Bone Augmentation Wedges:
• Painful, disabling joint disease of the knee secondary to: degenerative arthritis, rheumatoid arthritis, or post-traumatic arthritis, complicated by the presence of bone loss
• Salvage of previous unsuccessful total knee replacement or other surgical procedure, accompanied by bone loss
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。