RARA CRAFT DATABASE for FDA Medical Devices
510(k)K261984

FDA DEVICE FACTS

AssureTech Quick Cup Tests;AssureTech Multi-drug Urine Test Cup

Assure Tech., LLC

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJuly 17, 2026PRODUCT CODENFT

Indications for use

The AssureTech Quick Cup Tests are competitive binding, lateral flow immunochromatographic assays for qualitative and simultaneous detection of Amphetamine, Secobarbital, Buprenorphine, Oxazepam, Cocaine, EDDP, Fentanyl, Ecstasy, Propoxyphene, Morphine, Methadone, Phencyclidine, Oxycodone, Norfentanyl, Methamphetamine, Nortriptyline, 6-Monoacetylmorphine, Tramadol and Marijuana in human urine at the cutoff concentrations of: Drug (Identifier) Cut-off level Amphetamine(AMP) 1000 ng/mL or 500 ng/mL or 300 ng/mL Secobarbital (BAR) 300 ng/mL Buprenorphine(BUP) 10 ng/mL Oxazepam (BZO) 300 ng/mL Cocaine(COC) 300 ng/mL or 150 ng/mL EDDP 300 ng/mL Fentanyl (FYL) 1 ng/mL Ecstasy (MDMA) 500 ng/mL Propoxyphene (PPX) 300 ng/mL Morphine (MOR) 2000 ng/mL or 300 ng/mL Methadone(MTD) 300 ng/mL Phencyclidine (PCP) 25 ng/mL Oxycodone (OXY) 100 ng/mL Norfentanyl (NFYL) 5 ng/mL Methamphetamine(MET) 1000 ng/mL or 500 ng/mL or 300 ng/mL Nortriptyline (TCA) 1000 ng/mL 6-Monoacetylmorphine (6-MAM) 10 ng/mL Tramadol (TML) 100 ng/mL Marijuana (THC) 50 ng/mL or 20 ng/mL The single or multi-test cup can include any combination of the analytes listed above. However, only one cut-off concentration can be included per analyte per device. The test may yield positive results for the prescription drugs above when taken at or above prescribed doses. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. GC/MS or LC/MS is the preferred confirmatory method. For in vitro diagnostic use only. The AssureTech Multi-drug Urine Test Cup are competitive binding, lateral flow immunochromatographic assays for qualitative and simultaneous detection of Amphetamine, Secobarbital, Buprenorphine, Oxazepam, Cocaine, EDDP, Fentanyl, Ecstasy, Propoxyphene, Morphine, Methadone, Phencyclidine, Oxycodone, Norfentanyl, Methamphetamine, Nortriptyline, 6-Monoacetylmorphine, Tramadol and Marijuana in human urine at the cutoff concentrations of: Drug (Identifier) Calibrator Cut-off level Amphetamine(AMP) d-Amphetamine 1000 ng/mL or 500 ng/mL or 300 ng/mL Secobarbital (BAR) Secobarbital 300 ng/mL Buprenorphine(BUP) BUP-3-D-Glucuronide 10 ng/mL Oxazepam (BZO) Oxazepam 300 ng/mL Cocaine(COC) Benzoylecgonine 300 ng/mL or 150 ng/mL EDDP 2-Ethylidine-1,5-dimethyl-3,3-diphenylpyrrolidine 300 ng/mL Fentanyl (FYL) Fentanyl 1 ng/mL Ecstasy (MDMA) 3,4-Methylenediioxy-MET 500 ng/mL Propoxyphene (PPX) D-Propoxyphene 300 ng/mL Morphine (MOR) Morphine 2000 ng/mL or 300 ng/mL Methadone(MTD) Methadone 300 ng/mL Phencyclidine (PCP) Phencyclidine 25 ng/mL Oxycodone (OXY) Oxycodone 100 ng/mL Norfentanyl (NFYL) Norfentanyl 5 ng/mL Methamphetamine(MET) Methamphetamine 1000 ng/mL or 500 ng/mL or 300 ng/mL Nortriptyline (TCA) Nortriptyline 1000 ng/mL 6-Monoacetylmorphine (6-MAM) 6-Monoacetylmorphine 10 ng/mL Tramadol (TML) Cis-Tramadol 100 ng/mL Marijuana (THC) 11-nor-△9-THC-9-COOH 50 ng/mL or 20 ng/mL The single or multi-test cup can include any combination of the analytes listed above, with and without on-board adulteration tests. However, only one cut-off concentration can be included per analyte per device. It is for in vitro diagnostic use only. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. GC/MS or LC/MS is the preferred confirmatory method. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: September 1, 2026