Indications for use

The QIAstat-Dx BCID GN Plus AMR Panel is an automated qualitative multiplexed real-time PCR-based in vitro diagnostic test intended for use with the QIAstat-Dx Analyzer 2.0. The QIAstat-Dx BCID GN Plus AMR Panel is capable of simultaneous detection and identification of multiple gram-negative bacterial targets and selected genetic determinants associated with antimicrobial resistance. The following gram-negative bacteria are identified and differentiated using the QIAstat-Dx BCID GN Plus AMR Panel:

• Acinetobacter calcoaceticus-baumannii complex

• Bacteroides fragilis

• Enterobacter spp.

• Escherichia coli

• Haemophilus influenzae

• Klebsiella spp.

• Neisseria meningitidis (encapsulated)

• Proteus spp.

• Pseudomonas aeruginosa

• Salmonella spp.

• Serratia spp.

• Stenotrophomonas maltophilia

• Pan Enterobacterales The QIAstat-Dx BCID GN Plus AMR Panel contains assays for the detection of the following genetic determinants of resistance:

• aac(6’)-lb

• ampC (CMY/LAT/DHA/FOX)

• armA

• CTX-M

• GES

• IMP

• KPC

• NDM

• OXA-23

• OXA-24/40

• OXA-48-like

• OXA-58

• PER

• SHV

• SPM

• TEM

• VEB

• VIM The QIAstat-Dx BCID GN Plus AMR Panel contains assays for the detection of genetic determinants associated with resistance to aminoglycosides (aac(6')-lb and armA), penicillins and cephalosporins (ampC [CMY/LAT/DHA/FOX], CTX-M, GES, PER, SHV, TEM, and VEB), and carbapenems (GES, IMP, KPC, NDM, OXA-23, OXA-24/40, OXA-48-like, OXA-58, SPM, and VIM). The antimicrobial resistance gene detected may or may not be associated with the agent responsible for disease. Negative results for certain antimicrobial resistance assays do not indicate susceptibility, as multiple mechanisms of resistance exist. The QIAstat-Dx BCID GN Plus AMR Panel is intended for use in patients suspected of having bacterial infections identified as gram-negative via Gram stain in positive blood culture samples. The test is performed on blood culture samples identified as positive by a continuous monitoring blood culture system that demonstrates the presence of gram-negative bacteria via Gram stain. The QIAstat-Dx BCID GN Plus AMR Panel is intended to aid in the diagnosis of specific pathogens of bloodstream infection and select determinants of antimicrobial-resistance. Results should be used in conjunction with additional laboratory testing, e.g. sub-culturing of positive blood cultures for identification of organisms not detected by QIAstat-Dx BCID GN Plus AMR Panel and susceptibility testing and clinical presentation must be taken into consideration for patient management decisions. Negative results do not preclude the presence of pathogens that are not detected by this test. Positive QIAstat-Dx BCID GN Plus AMR Panel results do not rule out infection or co-infection with organisms not included in the QIAstat-Dx BCID GN Plus AMR Panel. Negative AMR results do not preclude the presence of other antimicrobial resistance mechanisms, and the absence of a resistance gene does not necessarily predict susceptibility to a particular drug nor predict therapeutic failure.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: October 7, 2026