IMAGEREADY MR CONDITIONAL PACING SYSTEM AND INGEVITY PACE/SENSE LEAD

Boston Scientific

Verified FDA Record identity for medical-device development research. This overview uses only fields stated in the FDA Record and is not a Device Description.医療機器開発の調査用に、確認済みの FDA Record の識別情報を示しています。この概要は FDA Record に記載された項目だけによるもので、機器説明ではありません。

DECISION DATEApril 25, 2016PRODUCT CODELWP

Indications for use

II. A. Ingenio and Accolade MRI Pacemaker Device Indications

The Ingenio and Accolade MRI pacemakers are indicated for the treatment of the following conditions:

• Symptomatic paroxysmal or permanent second- or third-degree AV block

• Symptomatic bilateral bundle branch block

• Symptomatic paroxysmal or transient sinus node dysfunction with or without associated AV conduction disorders (i.e., sinus bradycardia, sinus arrest, sinoatrial [SA] block)

• Bradycardia-tachycardia syndrome, to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias

• Neurovascular (vaso-vagal) syndromes or hypersensitive carotid sinus syndromes

Adaptive-rate pacing is indicated for patients exhibiting chronotropic incompetence and who may benefit from increased pacing rates concurrent with increases in minute ventilation and/or level of physical activity.

Dual-chamber and atrial tracking modes are also indicated for patients who may benefit from maintenance of AV synchrony.

Dual chamber modes are specifically indicated for treatment of the following:

• Conduction disorders that require restoration of AV synchrony, including varying degrees of AV block

• VVI intolerance (i.e., pacemaker syndrome) in the presence of persistent sinus rhythm

• Low cardiac output or congestive heart failure secondary to bradycardia

II. B. INGEVITY™ Pace/Sense Lead and Accessories Intended Use/Indications

The intended use/indication information listed below is presented as written in the device labeling.

II.C.1. Passive-fixation Non-MRI Models 7631, 7632, 7635 and 7636 and MRI Models 7731, 7732, 7735 and 7736

This Boston Scientific lead is indicated for use as follows:

• Intended for chronic pacing and sensing in the right atrium (Preformed Atrial J) or right ventricle (Straight) when used with a compatible pulse generator.

II.C.2. Active-fixation Non-MRI Models 7640, 7641, and 7642 and MRI Models 7740, 7741, and 7742

This Boston Scientific lead is indicated for use as follows:

• Intended for chronic pacing and sensing in the right atrium and/or right ventricle when used with a compatible pulse generator.

II.C.3. Slit Suture Sleeve Accessory Model 6402

The intended use of the slit suture sleeve accessory is:

• Use to secure and immobilize Boston Scientific INGEVITY™ leads at the venous entry site.

II.C.4. Delivery Stylet Models 5003, 5004, 5005, 5012, 5013, and 5014

The delivery stylet accessory is indicated for us as follows:

• For use with Boston Scientific implantable transvenous leads.

See the full product information製品情報をすべて見るには