PMAP160017S091

FDA DEVICE FACTS

MiniMed 780G System

Medtronic Minimed, Inc.

Verified FDA Record identity for medical-device development research. This overview uses only fields stated in the FDA Record and is not a Device Description.医療機器開発の調査用に、確認済みの FDA Record の識別情報を示しています。この概要は FDA Record に記載された項目だけによるもので、機器説明ではありません。

DECISION DATEApril 21, 2023PRODUCT CODEOZP

Indications for use

The MiniMed 780G system is indicated for use with either the Guardian Sensor (3)/Guardian Link (3) Transmitter, or with the Guardian 4 sensor/Guardian 4 transmitter Indications for use for the MiniMed 780G system are provided for each of the two system configurations separately:

MiniMed 780G System for use with Guardian Sensor (3)/Guardian Link (3) Transmitter

MiniMed 780G System The MiniMed 780G system is intended for continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable amounts for the management of type 1 diabetes mellitus in persons seven years of age and older requiring insulin. The system is also intended to continuously monitor glucose values in the fluid under the skin. The MiniMed 780G system includes SmartGuard (SG) technology, which can be programmed to automatically adjust insulin delivery based on continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the SG value falls below or is predicted to fall below predefined threshold values.

The MiniMed 780G system consists of the following devices:

• MiniMed 780G insulin pump

• Guardian Link (3) transmitter

• Guardian Sensor (3)

• One-press serter

• Accu-Chek™ Guide Link blood glucose meter

• Accu-Chek™ Guide Test Strips

The system requires a prescription from a healthcare professional.

Guardian Sensor (3) The Guardian Sensor (3) is intended for use with the MiniMed 780G system, MiniMed 770G system, MiniMed 670G system, MiniMed 630G system, and Guardian Connect system to continuously monitor glucose levels in persons with diabetes.

The sensor is intended for single use and requires a prescription. The Guardian Sensor (3) is indicated for seven days of continuous use.

The Guardian Sensor (3) is not intended to be used directly to make therapy adjustments while the MiniMed 780G system is operating in manual mode. All therapy adjustments in manual mode should be based on measurements obtained using a blood glucose meter and not on values provided by the Guardian Sensor (3).

The Guardian Sensor (3) has been studied and is approved for use in the systems, insertion sites, and ages listed in the following table:

System Approved Age Sensor Insertion Site MiniMed 780G system 7- 13 14 and older Abdomen and Buttocks Abdomen and Arm MiniMed 770G system 2-13 14 and older Abdomen and Buttocks Abdomen and Arm

System Approved Age Sensor Insertion Site MiniMed 670G system 7-13 14 and older Abdomen and Buttocks Abdomen and Arm MiniMed 630G system 14 and older Abdomen and Arm Guardian Connect system 14 and older Abdomen and Arm

One-press Serter The serter is used as an aid for inserting the sensor. It is indicated for single-patient use and it is not intended for multiple-patient use.

Guardian Link (3) Transmitter The Guardian Link (3) Transmitter is intended for use with the MiniMed 780G system. The Guardian Link (3) Transmitter powers the glucose sensor, collects and calculates sensor data, and wirelessly sends the data to the MiniMed 780G insulin pump. The transmitter is intended for single-patient multi-use.

Accu-Chek™ Guide Link Blood Glucose Monitoring System The Accu-Chek™ Guide Link Blood Glucose Monitoring System is comprised of the Accu- Chek™ Guide Link meter and the Accu-Chek™ Guide test strips.

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control.

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended for in - vitro diagnostic single-patient use by people with diabetes.

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended to be used by a single person and should not be shared.

This system is not for use in diagnosing or screening for diabetes mellitus and not for neonatal use.

Alternative site testing should be done only during steady-state times (when glucose is not changing rapidly).

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended to be used to wirelessly transmit glucose values to the MiniMed 780G system and MiniMed 770G system with Bluetooth wireless technology through the use of Bluetooth low energy communication.

MiniMed 780G System for use with Guardian 4 Sensor/Guardian 4 Transmitter

MiniMed 780G System The MiniMed 780G system is intended for continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable amounts for the

management of type 1 diabetes mellitus in persons seven years of age and older requiring insulin. The system is also intended to continuously monitor glucose values in the fluid under the skin. The MiniMed 780G system includes SmartGuard (SG) technology, which can be programmed to automatically adjust insulin delivery based on continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the SG value falls below or is predicted to fall below predefined threshold values.

The MiniMed 780G system consists of the following devices:

• MiniMed 780G insulin pump

• Guardian 4 transmitter

• Guardian 4 sensor

• One-press serter

• Accu-Chek™ Guide Link blood glucose meter

• Accu-Chek™ Guide Test Strips

The system requires a prescription from a healthcare professional.

Guardian 4 Sensor The Guardian 4 Sensor is intended for use with the MiniMed 780G system and the Guardian 4 transmitter to continuously monitor glucose levels for the management of diabetes.

The sensor is intended for single use and requires a prescription. The Guardian 4 sensor is indicated for up to seven days of continuous use.

The Guardian 4 sensor is not intended to be used directly to make therapy adjustments while the MiniMed 780G is operating in manual mode. All therapy adjustments in manual mode should be based on measurements obtained using a blood glucose meter and not on values provided by the Guardian 4 sensor.

The Guardian 4 sensor has been studied and is approved for use in the systems, insertion sites, and ages listed in the following table.

System Age Sensor Insertion Site MiniMed 780G system 7 years and older Arm

One-press Serter The serter is used as an aid for inserting the sensor. It is indicated for single-patient use and it is not intended for multiple-patient use.

Guardian 4 Transmitter The Guardian 4 transmitter is intended for use with the MiniMed 780G system and Guardian 4 sensor to monitor glucose levels for the management of diabetes.

Accu-Chek™ Guide Link Blood Glucose Monitoring System

The Accu-Chek™ Guide Link Blood Glucose Monitoring system is comprised of the Accu- Chek™ Guide Link meter and the Accu-Chek Guide test strips.

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control.

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended for in - vitro diagnostic single-patient use by people with diabetes.

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended to be used by a single person and should not be shared.

This system is not for use in diagnosing or screening for diabetes mellitus and not for neonatal use.

Alternative site testing should be done only during steady-state times (when glucose is not changing rapidly).

The Accu-Chek™ Guide Link Blood Glucose Monitoring System is intended to be used to wirelessly transmit glucose values to the MiniMed 780G system and MiniMed 770G system with Bluetooth wireless technology through the use of Bluetooth low energy communication.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。